邢超,奚鑫泽,何鑫,李胜男,刘明群.多端直流输电系统中限流电抗器配置研究[J].电测与仪表,2023,60(5):72-78.
Xing Chao,Xi Xinze,He Xin,Li Shengnan,Liu Mingqun.Research on configuration of current limiting reactor in multi-terminal HVDC system[J].Electrical Measurement & Instrumentation,2023,60(5):72-78.
多端直流输电系统中限流电抗器配置研究
Research on configuration of current limiting reactor in multi-terminal HVDC system
DOI:10.19753/j.issn1001-1390.2023.05.010
中文关键词:  限流电抗器  多端柔性直流输电  直流断路器
英文关键词:current-limiting reactor, multi-terminal flexible DC transmission, DC circuit breaker
基金项目:国家自然科学基金项目( 51707026)
              
作者中文名作者英文名单位
邢超Xing Chao云南电网有限责任公司电力科学研究院, 昆明 650217
奚鑫泽Xi Xinze云南电网有限责任公司电力科学研究院, 昆明 650217
何鑫He Xin云南电网有限责任公司电力科学研究院, 昆明 650217
李胜男Li Shengnan云南电网有限责任公司电力科学研究院, 昆明 650217
刘明群Liu Mingqun云南电网有限责任公司电力科学研究院, 昆明 650217
摘要点击次数: 1179
中文摘要:
      多端直流电网的故障暂态发展极快,因此在实际工程中一般需要配置限流电抗器来抑制故障电流的上升。但是,限流电抗器的配置在限制故障电流的同时,也会对非故障的部分产生影响,因此文中对多端直流输电系统中限流电抗器的配置进行了研究。建立了多端直流输电系统的故障计算模型,并给出了包含断路器各动作阶段的系统状态量的计算方法;分析了多端直流输电系统中限流电抗器的配置需要考虑的问题;以四端直流输电系统为例,针对不同的限流电抗器配置情况下的直流系统故障过程进行了仿真计算,并根据计算结果分析了限流电抗器对系统最大故障电流、换流站闭锁情况、直流母线过压情况和过电流衰减时间等问题的影响。
英文摘要:
      The fault transient of multi-terminal DC power grid develops very fast, so it is necessary to configure current-limiting reactor to restrain the rise of fault current in practical engineering. However, the configurations of current-limiting reactor will also impact on non-fault part while limiting the fault current. Therefore, configurations of current-limiting reactor in multi-terminal HVDC transmission system are studied in this paper. Firstly, the fault calculation model of multi-terminal DC transmission system is established, and the calculation method of system state quantity including each action stage of circuit breaker is given. Then, this paper analyzes the problems that are considered in the configuration of a current limiting reactor in multi-terminal HVDC transmission system. Finally, taking four-terminal HVDC transmission system as an example, the fault process of the DC system under different current-limiting reactor configurations is simulated and calculated. Based on the calculation results, the influence of current-limiting reactor on the maximum fault current, the blocking condition of converter station, overvoltage of DC bus and decay time of over-current of a system is analyzed.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司