• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
严勤,李世松,叶远誉,熊志凌,赵伟,熊茹.一种适用于大体积弱磁材料磁导率测量的方法[J].电测与仪表,2022,59(8):161-165.
yan qin,li shi song,ye yuan yu,xiong zhi ling,zhao wei,xiong ru.A permeability measurement approach for weak magnetic materials with large volume[J].Electrical Measurement & Instrumentation,2022,59(8):161-165.
一种适用于大体积弱磁材料磁导率测量的方法
A permeability measurement approach for weak magnetic materials with large volume
DOI:10.19753/j.issn1001-1390.2002.08.022
中文关键词:  弱磁材料  磁场测量  磁导率  弱磁探测  磁特性
英文关键词:weak magnetic material, magnetic field measurement, permeability, weak magnetic measurement, magnetic property
基金项目:
                 
作者中文名作者英文名单位
严勤yan qin国网江西省电力有限公司
李世松li shi song清华大学
叶远誉ye yuan yu国网江西省电力有限公司
熊志凌xiong zhi ling国网江西省电力有限公司供电服务管理中心
赵伟zhao wei清华大学
熊茹xiong ru国网江西省电力有限公司供电服务管理中心
摘要点击次数: 1486
中文摘要:
      磁导率表征着磁性材料基本的电磁物理特性,是磁性材料的重要参数之一。对于高磁导率(相对磁导率μr>100)材料,测量其磁导率的方法比较成熟,多采用加工成闭合环行铁芯,在其上缠绕线圈、施加激励电流,进而测量感应电压并再换算的方法确定。而对弱磁材料(相对磁导率μr在1附近)磁导率的测量,则需要设计特殊的磁化装置,对其特定形状的样品进行测量。本文针对已有弱磁材料磁导率测量方法因需要取样,会改变被测弱磁材料磁特性的问题,提出了一种无需机械加工弱磁材料样品、不会造成被测弱磁材料磁特性改变、适用于大体积弱磁材料磁导率测量的新方法。以有限元仿真分析计算,确定了该测量方法的适用范围及可能的主要误差来源,验证了它的合理可行性。
英文摘要:
      The magnetic permeability, μ, is an important material parameter, which reflects fundamental electromagnetic properties of the material. For high permeability (relative permeability μr> 100) measurement, materials are mostly measured by a closed-loop magnetic core and current-carrying windings. For the magnetic permeability measurement of a weak magnetic material (relative permeability μr is near 1), a special shape of test samples is typically required in order to fit the magnetization circuit, and machining the sample may cause damage to the material magnetic property and yield incorrect measurement result. In this study, we present a method for measuring the permeability of a large-volume weak magnetic material. The proposed approach has no special requirements on the shape of the measurement sample, thereby can avoid the permeability change caused by mechanical processing. Through finite element simulation, the measurement range and main error sources of this permeability measurement method are discussed.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司