黄龙平,林慧,胡立坤.微型光谱仪数据采集系统设计与标定[J].电测与仪表,2023,60(9):177-182.
Huang Longping,Lin Hui,Hu Likun.Design and calibration of data acquisition system for miniature spectrometer[J].Electrical Measurement & Instrumentation,2023,60(9):177-182.
微型光谱仪数据采集系统设计与标定
Design and calibration of data acquisition system for miniature spectrometer
DOI:10.19753/j.issn1001-1390.2023.09.026
中文关键词:  微型光谱仪  CMOS图像传感器  数据采集系统  波长标定  线性
英文关键词:miniature spectrometer, CMOS image sensor, data acquisition system, wavelength calibration, linearity
基金项目:国家自然科学基金项目( 61863002)
        
作者中文名作者英文名单位
黄龙平Huang Longping广西大学 电气工程学院,南宁 530004
林慧Lin Hui中国科学院 深圳先进技术研究院,广东 深圳 518000
胡立坤Hu Likun广西大学 电气工程学院,南宁 530004
摘要点击次数: 1062
中文摘要:
      针对目前多采用CCD作为微型光谱仪的光电探测,文中介绍了使用高性能线性CMOS图像传感器S11639-01设计的一款微型光谱仪。图像传感器的驱动及光谱仪数据采集系统控制均采用ARM Cortex-M7内核的32位处理器STM32H743芯片。系统硬件电路结构紧凑、数据采集分辨率高、传输实时性好。光谱仪的光路结构由入射狭缝、平场凹面光栅、线阵CMOS探测器组成,该结构相对简单,有利于光谱仪的微型化。采用美国海洋光学标准低压汞灯和卤钨灯对光谱仪进行实验测试,实验所得数据通过波长标定、光谱自动寻峰等技术进行处理,可以得到该系统光谱响应范围220 nm~950 nm,光谱波长标定误差低于0.05 nm,系统最小分辨率1.153 nm,线性度在99.898%以上。
英文摘要:
      Aiming at the current use of CCD as a miniature spectrometer for photoelectric detection, this paper introduces a miniature spectrometer designed using a high-performance linear CMOS image sensor S11639-01. The drive of the image sensor and the control of the data acquisition system of the spectrometer are all based on the 32-bit processor STM32H743 chip of ARM Cortex-M7 core. The system hardware circuit has a compact structure, high data acquisition resolution, and good real-time transmission. The optical path system structure of the spectrometer consists of an entrance slit, a flat-field concave grating, and a linear array CMOS detector. The structure is relatively simple, which is conducive to the miniaturization of the spectrometer. The spectrometer is tested by using the American ocean optics standard low-pressure mercury lamp and tungsten halogen lamp. The experimental data is processed by wavelength calibration and automatic peak-spectrum technology, and the spectral response range of system is 220 nm~950 nm. The calibration error of spectral wavelength is less than 0.05 nm, the minimum resolution of the system is 1.153 nm, and the linearity is above 99.898%.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司