• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
孙丽玲,尹思杰,王艳娟.电网电压骤升时DFIG定子磁链暂态全过程及其影响因素研究[J].电测与仪表,2022,59(8):86-91.
Sun liling,Yin Sijie,Wang Yanjuan.Transient whole process and influencing factors of stator flux in grid voltage swell of DFIG[J].Electrical Measurement & Instrumentation,2022,59(8):86-91.
电网电压骤升时DFIG定子磁链暂态全过程及其影响因素研究
Transient whole process and influencing factors of stator flux in grid voltage swell of DFIG
DOI:10.19753/j.issn1001-1390.2002.08.011
中文关键词:  双馈感应发电机  高电压穿越  暂态特性  骤升模式  时间间隔
英文关键词:doubly-fed  induction generator, high  voltage ride  through,transient  characteristics, swell  model, time  interval
基金项目:51277077,国家自然科学基金项目( 项目编号)
        
作者中文名作者英文名单位
孙丽玲Sun liling华北电力大学 电气与电子工程学院
尹思杰Yin Sijie华北电力大学 电气与电子工程学院
王艳娟Wang Yanjuan国网冀北电力有限公司唐山市
摘要点击次数: 913
中文摘要:
      双馈感应发电机(DFIG)的高电压穿越问题中,定子磁链的暂态特性研究是实现高电压穿越运行的基础和依据,而常规研究大多只针对电网电压单一骤升模式进行分析,且未考虑故障恢复后定子磁链的动态过程,使其暂态特性分析不全面。本文对电压不同骤升模式时的定子磁链瞬态过程进行了研究,对比分析了影响定子磁链暂态特性的一些因素。电网电压的上升模式不同,定子磁链的暂态特性也不一样,且模式I的暂态衰减分量远大于模式II;相邻两次电压上升数值相同且时间间隔为 时,能够最小化定子磁链的瞬态衰减分量。仿真结果证明了理论分析的正确性,本文的研究内容对掌握DFIG的动态过程和高电压穿越控制策略的制定具有一定的参考价值。
英文摘要:
      In the high voltage ride through problem of doubly fed induction generator (DFIG), the study of transient characteristics of stator flux is the basis and basis for realizing high voltage ride through operation, While the conventional studies only for single mode analysis of grid voltage swell, and ignored the fault dynamic change of stator flux recovery after the fault recovery, so that the transient characteristic analysis is not comprehensive. In this paper, the whole process of stator flux transient in different surge modes of grid voltage is studied. On this basis, the factors influencing the transient characteristics of stator flux are compared and analyzed. Grid voltage surge mode is different, the stator flux transient characteristics are also different, and the transient attenuation component of mode II is much smaller than mode I; When the voltage rise of the adjacent grid is the same and the time interval is , the transient attenuation component of the stator flux can be minimized. The simulation results verify the correctness of the theoretical analysis, The research of this paper has certain reference value to master the dynamic process of DFIG and the formulation of high voltage ride through control strategy.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司