吴元相,刘开培,秦亮,郑欣,王新华.高压直流电能计量系统计量误差研究[J].电测与仪表,2022,59(9):146-152.
Wu Yuanxiang,Liu Kaipei,Qin Liang,Zheng Xin,Wang Xinhua.Research on measurement error of high voltage direct current energy measurement system[J].Electrical Measurement & Instrumentation,2022,59(9):146-152.
高压直流电能计量系统计量误差研究
Research on measurement error of high voltage direct current energy measurement system
DOI:10.19753/j.issn1001-1390.2002.09.020
中文关键词:  高压直流电能计量  计量误差  准确级  损耗电量  误差均值
英文关键词:HVDC  energy measurement, measurement  error, accuracy  level, power  loss, error  mean
基金项目:国网湖北电力公司科技项目(521532170015)
              
作者中文名作者英文名单位
吴元相Wu Yuanxiang武汉大学 电气与自动化学院
刘开培Liu Kaipei武汉大学 电气与自动化学院
秦亮Qin Liang武汉大学 电气与自动化学院
郑欣Zheng Xin国网湖北省电力公司计量中心
王新华Wang Xinhua深圳市中电电力技术股份有限公司
摘要点击次数: 1456
中文摘要:
      高压直流电能计量的准确性对直流系统电量结算和相关技术指标计算有直接影响。针对典型的高压直流电能计量系统,考虑系统中各装置准确级及误差的概率分布,结合工程实际使用的电能计量算法,建立了高压直流电能计量误差模型。分析表明在不同装置准确级组合情况下,直流电能计量系统的相对误差表现出与各环节误差分布的均值有关,直流侧总电能相对误差与换流单元正极和负极电能计量误差的均值有关。在换流站现场对直流电能表进行误差测试,得到被测直流电能表的计量误差情况。由于装置组合产生的整体误差会对系统损耗率较小的直流输电系统的损耗电能计量造成一定影响,因此应在计量装置满足准确级的基础上,适当增加周期性校准试验次数,并在调校过程中尽量降低装置的误差均值,从而提高高压直流电能计量的准确性。
英文摘要:
      As an important part of HVDC system, the accuracy of HVDC energy measurement has a direct impact on the power settlement and related technical index calculation. Aiming at the typical HVDC energy measurement system, considering the accuracy level of each device in the system and the probability distribution of the error, combined with the actual energy measurement algorithm used in the project, the error model of HVDC energy measurement is established. The simulation analysis shows that the relative error of DC power metering system is related to the mean value of error distribution of each link under the condition of different device accuracy level combination, and the relative error of total power on DC side is related to the mean value of positive and negative power metering error of converter unit. The error of DC energy meter is tested in the converter station, and the measurement error of DC energy meter is obtained. As the overall error caused by the combination of devices will have a certain impact on the loss energy measurement of the DC transmission system with a small loss rate of the system, it is necessary to increase the number of periodic calibration tests on the basis that the measurement device meets the accuracy level, and reduce the mean error of the device as much as possible in the calibration process, so as to improve the accuracy of the high-voltage DC energy measurement.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司