王尚鹏,唐登平,雷鸣,郑欣,夏天,田猛.智慧变电站计量系统综合误差模型研究[J].电测与仪表,2023,60(9):183-187.
Wang Shangpeng,Tang Dengping,Lei Ming,Zheng Xin,Xia Tian,Tian Meng.Research on composite error model of metering system in smart substations[J].Electrical Measurement & Instrumentation,2023,60(9):183-187.
智慧变电站计量系统综合误差模型研究
Research on composite error model of metering system in smart substations
DOI:10.19753/j.issn1001-1390.2023.09.027
中文关键词:  智慧变电站  计量系统  综合误差  采样前端
英文关键词:smart substation, metering system, composite error, front-end sampling
基金项目:国家自然科学基金项目( 51707135)
                 
作者中文名作者英文名单位
王尚鹏Wang Shangpeng国网湖北省电力有限公司计量中心,武汉 430080
唐登平Tang Dengping国网湖北省电力有限公司计量中心,武汉 430080
雷鸣Lei Ming国网湖北省电力有限公司计量中心,武汉 430080
郑欣Zheng Xin国网湖北省电力有限公司计量中心,武汉 430080
夏天Xia Tian国网湖北省电力有限公司计量中心,武汉 430080
田猛Tian Meng武汉大学 电子信息学院,武汉 430072
摘要点击次数: 1256
中文摘要:
      目前智慧变电站计量系统中单体设备的误差特性与检测方法研究日趋成熟,针对设备间误差关联和影响的系统级误差测试方法已得到使用验证。然而,对其综合误差的建模与分析工作尚未有效开展,导致智慧计量系统在误差配合、故障分析等方面缺乏参考依据,不便于在贸易结算关口使用。文章从传感、量化、组帧、插值、延时等影响智慧变电站计量系统误差的因素着手,建立了系统综合误差数学模型,并在各不同场景下对模型准确性进行了试验验证,结果表明该模型特别适用于智慧变电站计量系统综合误差分析,可为系统设计、试验、运维提供参考依据。
英文摘要:
      At present, the research on error characteristics and detection methods of individual equipment in smart substation metering system is becoming more and more mature, and the system-level error test method for error association and influence between devices has been validated. However, the modeling and analysis of its comprehensive errors have not been carried out effectively, which makes this type of metering systems lack of analytical basis for error tolerance fitting and disabled the legitimacy of the power-trading purpose of digital metering system. Starting from the factors affecting the metering system error of smart substation, such as sensing, quantization, framing, interpolation, delay, etc., a mathematical model of system composite error is established. And the accuracy of the model is tested and verified in different scenes. The results show that the model is especially suitable for the composite error analysis of metering system in smart substation, which can provide reference for design, test, operation and maintenance of system.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司