• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
王剑锋,王旭东,李峰,戚艳,邬斌扬,苏万华.考虑㶲损失的三联供系统容量配置与运行模式研究[J].电测与仪表,2024,61(1):113-118.
WANG Jianfeng,WANG Xudong,LI Feng,QI Yan,WU Binyang,SU Wanhua.Research on capacity allocation and operation mode of triple-generation system considering exergy loss[J].Electrical Measurement & Instrumentation,2024,61(1):113-118.
考虑㶲损失的三联供系统容量配置与运行模式研究
Research on capacity allocation and operation mode of triple-generation system considering exergy loss
DOI:10.19753/j.issn1001-1390.2024.01.017
中文关键词:  冷、热、电三联供系统  运行模式  容量配置
英文关键词:CCHP system, operation mode, capacity allocation
基金项目:天津市重点研发计划科技支撑重点项目(18YFZCGX00570);国网天津市电力公司科技项目(KJ19-1-17)
                 
作者中文名作者英文名单位
王剑锋WANG Jianfeng国网天津市电力公司,天津 300010
王旭东WANG Xudong国网天津市电力公司,天津 300010
李峰LI Feng天津大学 机械工程学院,天津 300350
戚艳QI Yan国网天津市电力公司电力科学研究院,天津 300384
邬斌扬WU Binyang天津大学 机械工程学院,天津 300350
苏万华SU Wanhua天津大学 机械工程学院,天津 300350
摘要点击次数: 645
中文摘要:
      节能减排一直是世界各国持续关注的热点问题,综合能源三联供系统因其具有更高的一次能源利用率而被广泛应用。针对综合能源三联供系统的容量配置和运行模式规划问题,提出考虑?损失的综合性能指标作为优化的目标函数,从高效、低碳、经济三个方面进行综合优化。以燃气轮机的容量和运行模式为设计变量,建立综合能源三联供系统容量配置与运行模式研究模型。将此方法应用到某宾馆建筑的联供系统进行分析,研究结果为:燃气轮机的最佳容量为200 kW,热电结合是最优的运行模式。在该模式下综合能源三联供系统较传统供能系统?损失率降低3.5 %,年综合碳排量减少593.7 t,年经济成本节约29.8 万元。该方法能够全面、客观地分析某容量、某种运行模式下的系统性能,为解决联供系统的运行规划问题提供参考。
英文摘要:
      Energy saving and emission reduction has always been a hot issue that countries in the world continue to care about. The triple-generation system of combined cooling, heating and power system is widely used because of its higher primary energy utilization. For the capacity allocation and operation mode planning of the combined cooling, heating and power system, a comprehensive evaluation index considering exergy loss is proposed as the objective funetion of optimization, and the function optimizes the system from three aspects of high efficiency, economy and low emission. Taking the capacity and operation mode of the gas turbine as design variables, the research model of capacity allocation and operation mode of triple-generation system is established. This method is applied to the co-generation system of a hotel building for analysis and planning. The research results show that the optimal capacity of the gas turbine is 200 kW , and the combinaion of heat and power is the optimal operation mode. Under this mode, the combined cooling, heating and power system has a 3.5 % lower exergy loss rate than the traditional energy supply system; the annual comprehensive emissions is reduced by 593. 7 t; the annual economic cost is saved by 298 000 yuan. This method can comprehensively and objectively analyze the system performance under a certain capacity and certain operation mode , which provides a reference for solving the operation planning problems of the combined cooling, heating and power system.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司