• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
传云,王维庆,王海云,武家辉.基于过渡电阻倾斜角的风电T接双电源系统自适应距离保护方案[J].电测与仪表,2024,61(3):138-144.
CHUAN Yun,WANG Weiqing,WAN Haiyun,WU Jiahui.Adaptive distance protection scheme of wind power T-connected dual power system based on transition resistance inclination angle[J].Electrical Measurement & Instrumentation,2024,61(3):138-144.
基于过渡电阻倾斜角的风电T接双电源系统自适应距离保护方案
Adaptive distance protection scheme of wind power T-connected dual power system based on transition resistance inclination angle
DOI:10.19753/j.issn1001-1390.2024.03.019
中文关键词:  风电T接  自适应距离保护  测量阻抗  过渡电阻  过渡电阻倾斜角
英文关键词:wind power T-connection, adaptive distance protection, measurement impedance, transition resistance, transition resistance inclination angle
基金项目:自治区重点实验室开放课题(2018D04005);国家自然科学基金(16670205);教育部创新团队(IRT_16R63);自治区高校科研计划自然科学重点项目(XJEDU2019I009)
           
作者中文名作者英文名单位
传云CHUAN Yun新疆大学可再生能源发电与并网控制教育部工程研究中心
王维庆WANG Weiqing新疆大学可再生能源发电与并网控制教育部工程研究中心
王海云WAN Haiyun新疆大学可再生能源发电与并网控制教育部工程研究中心
武家辉WU Jiahui新疆大学可再生能源发电与并网控制教育部工程研究中心
摘要点击次数: 556
中文摘要:
      针对风电T型接入高压配电网后传统距离保护可能发生误动、拒动的情况,研究相对应的保护方案意义重大。文章推导了风电T接点上、下游测量阻抗表达式,得出其包含的附加阻抗可能会使传统保护装置不正确动作。鉴于此,提出基于过渡电阻倾斜角的风电T接系统自适应距离保护方案。该方案自适应修正测量阻抗使其能跟踪到短路阻抗,有效消除附加阻抗对距离保护的影响。在MATLAB仿真软件中对方案进行仿真验证,结果表明该方案受故障点位置、过渡电阻、电源相位差及风电运行方式影响较小,可有效解决传统距离保护拒动或者误动的问题,提高电网的安全稳定性。
英文摘要:
      In view of the situation that the traditional distance protection may misoperate and refuse to operate after the wind power T-type is connected to the high-voltage distribution network, it is of great significance to study the corresponding protection scheme. First of all, this paper deduces the expressions of measurement impedance of upstream and downstream of wind power T-connection, and concludes that the additional impedance contained in it may make the traditional protection device not operate correctly. In view of this, an adaptive distance protection scheme of wind power T-connection system based on transition resistance inclination angle is proposed in this paper. The scheme can adaptively modify the measurement impedance so that it can track the short-circuit impedance and effectively eliminate the influence of additional impedance on distance protection. Finally, the scheme is verified by MATLAB simulation software. The results show that the proposed scheme is less affected by the fault location, transition resistance, power phase difference and wind power operation mode, which can effectively solve the problem of refusing to operate or misoperation of traditional distance protection, and improve the security and stability of power grid.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司