胡晓斌,张捷,薛桅.变电站电缆通道多参量采集和预警技术研究[J].电测与仪表,2023,60(10):161-165.
Hu Xiaobin,Zhang Jie,Xue Wei.Research on multi-parameter acquisition and early warning technology of substation cable channel[J].Electrical Measurement & Instrumentation,2023,60(10):161-165.
变电站电缆通道多参量采集和预警技术研究
Research on multi-parameter acquisition and early warning technology of substation cable channel
DOI:10.19753/j.issn1001-1390.2023.10.026
中文关键词:  变电站  电缆通道  多参量  预警系统  温度场  载流量
英文关键词:substation, cable channel, multi-parameter, early warning system, temperature field, current carrying capacity
基金项目:国家电网公司科技项目(项目编号:5218D01800D7)
        
作者中文名作者英文名单位
胡晓斌Hu Xiaobin国网江西省电力有限公司九江供电分公司
张捷Zhang Jie国网江西省电力有限公司
薛桅Xue Wei国网江西省电力有限公司瑞昌供电分公司
摘要点击次数: 1306
中文摘要:
      针对变电站电缆通道数量的不断增加,电缆分布众多,某条线路的故障会带来极大的安全隐患。文中提出一种变电站电缆通道多参量采集和预警系统的设计方案,重点研究电力电缆的温度场和载流量。通过有限元分析软件,建立了10 kV单芯电缆四回路标准敷设电缆沟的几何模型,并采用割线法计算稳态载流量。通过实验分析了不同工况下的温度场和载流量。结果表明,对于在线电缆温度监测,只需要对温度最高的电缆进行监测,电缆铺设密度过高会导致电缆的载流量下降。该研究为中国变电站电缆通道多参量采集和预警技术的发展提供一定的参考和借鉴。
英文摘要:
      In view of the increasing number of cable channels in substation and the large number of cables distribution, the fault of a certain line will bring great security hazard. A design scheme of multi- parameter acquisition and early warning system for cable channel in substation is proposed in this paper, focusing on the temperature field and current carrying capacity of power cable. Through the finite element analysis software, the geometric model of 10 kV single core cable four-loop standard laying cable trench is established, and the steady-state ampacity is calculated by secant method. The temperature field and current carrying capacity under different working conditions are analyzed by experiments. The results show that for on-line cables temperature monitoring, only the cable with the highest temperature is needed to be monitored, and if the cable laying density is too high, the current carrying capacity of the cable will decrease. The research provides some reference for the development of multi-parameter acquisition and early warning technology of substation cable channel in China.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司