周雪松,葛建鹏,马幼捷.二阶LADRC在风电并网逆变器网侧直流母线电压控制中的运用[J].电测与仪表,2024,61(3):182-191.
ZHOU Xuesong,GEJianpeng,MA Youjie.Application of second-order LADRC in grid side DC bus voltage control of wind power grid-connected inverter[J].Electrical Measurement & Instrumentation,2024,61(3):182-191.
二阶LADRC在风电并网逆变器网侧直流母线电压控制中的运用
Application of second-order LADRC in grid side DC bus voltage control of wind power grid-connected inverter
DOI:10.19753/j.issn1001-1390.2024.03.025
中文关键词:  风电并网  直流母线电压稳定控制  LADRC
英文关键词:wind power grid connection, DC bus voltage stability control, LADRC
基金项目:国家自然科学基金项目(51877152)
        
作者中文名作者英文名单位
周雪松ZHOU Xuesong天津理工大学天津市复杂系统控制理论与应用重点实验室
葛建鹏GEJianpeng天津理工大学天津市复杂系统控制理论与应用重点实验室
马幼捷MA Youjie天津理工大学 电气电子工程学院
摘要点击次数: 692
中文摘要:
      为提高风电并网系统中电网侧逆变器直流母线电压的稳定性和动态响应速度,文中设计一种无对象模型辅助的二阶线性自抗扰控制技术(linear active disturbance rejection control, ADRC)以取代电压外环的PI控制器,从而形成一种新的双闭环控制结构。文中利用频域分析法分析了ADRC控制器的稳定性、跟踪性和抗扰能力;最后在3.6 MW直驱永磁同步风力发电机组的物理实验平台中验证了该控制结构的可行性,将传统PI控制和文中所提出的控制模式在不同工作条件下的控制效果进行比较。实验结果表明,该文章设计的控制方案优于传统的PI控制器,具有良好的抗干扰性和鲁棒性,大大减少直流侧母线电压波动所造成的影响。
英文摘要:
      In order to improve the stability and dynamic response speed of the DC bus voltage of the grid side inverter in the wind power grid-connected system, a second-order linear active disturbance rejection control (LADRC) without object model assistance is designed to replace the PI controller of the voltage outer loop, thus forming a novel double closed-loop control structure. In this paper, the frequency domain analysis method is utilized to analyze the stability, tracking and anti-interference ability of ADRC controller. Finally, the feasibility of the proposed control structure is verified in the physically realized mechatronic systems of 3.6MW direct drive permanent magnet synchronous wind turbine, and the control effect of traditional PI control and the control mode proposed in this paper is carried out comparison under different working conditions. The experimental results show that the control scheme designed in this paper is superior to the traditional PI controller, and has good anti-interference and robustness, greatly reducing the impact of DC side bus voltage fluctuation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司