刘健,刘海,杨晓西,张志华.零序电流互感器配大电阻的配电网单相接地故障检测[J].电测与仪表,2023,60(10):92-97.
Liu Jian,Liu Hai,Yang Xiaoxi,Zhang Zhihua.Single-phase grounding fault detection based on zero-sequence current transformer with large resistance[J].Electrical Measurement & Instrumentation,2023,60(10):92-97.
零序电流互感器配大电阻的配电网单相接地故障检测
Single-phase grounding fault detection based on zero-sequence current transformer with large resistance
DOI:10.19753/j.issn1001-1390.2023.10.015
中文关键词:  配电网  零序电流互感器  单相接地  继电保护  单相接地选线
英文关键词:distribution network, zero-sequence current transformer, single-phase grounding fault, relay protection, single-phase grounding line selection
基金项目:国家自然科学( U1766208)资助
           
作者中文名作者英文名单位
刘健Liu Jian西安科技大学 陕西省电力科学研究院
刘海Liu Hai西安科技大学
杨晓西Yang Xiaoxi陕西省电力科学研究院
张志华Zhang Zhihua陕西省电力科学研究院
摘要点击次数: 1123
中文摘要:
      为了简化配电网单相接地故障检测装置的构成和增强单相接地故障特征,探索了一种基于零序电流互感器配较大负载电阻的配电网单相接地故障检测方法。分析了零序电流互感器配大负载电阻时的特性,并通过仿真和实验手段验证了其正确性。在此基础上,研究了二次侧电阻的参数选取问题,探讨了所研究方法在中性点不接地配电网用户侧分界开关单相接地保护装置和变电站单相接地选线装置中的应用,结合典型例子采用数字仿真的方法验证了其可行性,并与传统方法对比分析,结果表明所论述方法在进行单相接地选线时具有故障特征更明显的特点,在实现用户侧单相接地保护时可使电路更简单。
英文摘要:
      To simplify the circuit and increase the fault signature for single-phase grounding faults detection device in distribution networks, a single-phase grounding fault detection method based on zero-sequence current transformer with large resistance is proposed. The characteristics of zero-sequence current transformers with large secondary resistance are investigated, and its correctness is verified by simulation and experiment results. On this basis, the parameter selection of the secondary side resistance is studied. The applications of the proposed methods in relay protection of the customer circuit breaker and the single-phase grounding line selection in substations are described with typical examples, the feasibility of which is verified by the digital simulation method. Compared with the traditional approaches, the results show that the proposed method makes the detection circuit simpler and increases the fault signature for single-phase grounding protection on the user side.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司