• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
赵长春,邓茂军,张艳超,樊占峰,倪传坤,余高旺.智慧变电站集群测控功能冗余切换方案研究[J].电测与仪表,2021,58(9):158-165.
ZHAO Changchun,DENG Maojun,ZHANG Yanchao,FAN Zhanfeng,NI Chuankun,YU Gaowang.Research on Redundant Switching Scheme for Cluster Measurement and Control Functions in Smart Substation[J].Electrical Measurement & Instrumentation,2021,58(9):158-165.
智慧变电站集群测控功能冗余切换方案研究
Research on Redundant Switching Scheme for Cluster Measurement and Control Functions in Smart Substation
DOI:10.19753/j.issn1001-1390.2021.09.024
中文关键词:  智慧变电站  集群测控  虚拟化  冗余切换
英文关键词:smart substation  cluster measurement and control  virtualization  redundant switch
基金项目:中原科技创新领军人才计划资助(204200510007)
                 
作者中文名作者英文名单位
赵长春ZHAO Changchun国网吉林省电力有限公司检修公司
邓茂军DENG Maojun许继电气股份有限公司
张艳超ZHANG Yanchao许继电气股份有限公司
樊占峰FAN Zhanfeng许继电气股份有限公司
倪传坤NI Chuankun许继电气股份有限公司
余高旺YU Gaowang许继电气股份有限公司
摘要点击次数: 1595
中文摘要:
      智能变电站测控装置仍采用单套配置,存在单点故障导致测控功能失效的隐患,无法完全适应智能变电站无人值守的要求。针对“单间隔+集群测控”、“双套集群测控”两种配置模式分别提出了相应的测控功能冗余切换方案。通过配置集群测控装置,采用测控功能虚拟化思想、定值及软压板状态同步、模型及配置等价实现等关键技术,实现了集群测控装置的功能等价、模型等价及配置等价,解决了智慧变电站测控装置故障时测控功能的冗余切换问题,提升了智慧变电站监控系统的可靠性。通过试验验证和工程应用,验证了方案的有效性和适应性。
英文摘要:
      The intelligent substation measurement and control device still adopts a single set of configuration, and there is a hidden danger that a single point of failure causes the measurement and control function to fail, and it cannot fully meet the requirements of unattended intelligent substations. For the two configuration modes of "single interval + cluster measurement and control" and "double sets of cluster measurement and control", corresponding redundant switching schemes for measurement and control functions are proposed.By configuring the cluster measurement and control device, adopting key technologies such as measurement and control function virtualization idea, fixed value and soft plate state synchronization, model and configuration equivalence realization, the device can run multiple interval virtual measurement and control units at the same time, realizing the functions of the cluster measurement and control device, etc. Cost, model equivalence and configuration equivalence solve the problem of redundant switching of measurement and control functions when the measurement and control device of the smart substation fails, and improve the reliability of the monitoring system of the smart substation.Through test verification and engineering application, the validity and adaptability of the scheme are verified.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司