梁栋,徐丙垠,刘洋,方陈.基于差分方向行波的脉冲电流电缆故障测距方法[J].电测与仪表,2021,58(7):150-156.
LIANG Dong,XU Bing-yin,LIU Yang,FANG Chen.Impulse current cable fault location method based on differential directional traveling waves[J].Electrical Measurement & Instrumentation,2021,58(7):150-156.
基于差分方向行波的脉冲电流电缆故障测距方法
Impulse current cable fault location method based on differential directional traveling waves
DOI:10.19753/j.issn1001-1390.2021.07.021
中文关键词:  电缆故障  测距  自动化  脉冲电流法  差分方向行波  相关分析
英文关键词:cable faults, location, automation, impulse current method, differential directional traveling waves, correlation analysis
基金项目:国家重点研发计划资助项目(2017YFB0902800),国家电网公司科技资助项目(52094017003D)
           
作者中文名作者英文名单位
梁栋LIANG Dong山东理工大学农业工程与食品科学学院
徐丙垠XU Bing-yin山东理工大学电气与电子工程学院
刘洋LIU Yang山东理工大学电气与电子工程学院
方陈FANG Chen国网上海市电力公司电力科学研究院
摘要点击次数: 1566
中文摘要:
      针对脉冲电流电缆故障测距法测试波形复杂、数据分析自动化尚未实现的问题,提出了构建差分方向行波对并以相关分析提取行波往返时间的方法,实现脉冲电流法测试数据自动分析。基于行波信号在电缆中的传播特性,分析了传播畸变中衰减畸变和色散畸变对相关分析峰值位置的影响,推得低频频带的色散畸变是影响相关分析准确性的主要因素。提出了利用导引电缆两端同型号线性耦合器的电流测量数据对电流行波进行方向解耦的方法,采用首脉冲触发方式进行时钟同步,实现了低成本、宽频带、高可靠性的方向行波构建,避免了电流互感器和电压互感器在宽频带下传递特性不一致的问题。仿真结果显示,文中方法对于非近端故障的测距误差不超过0.7%。对高阻故障位于207±1m的电缆进行实际测试,测距结果为207.26m,相对误差不大于0.61%。
英文摘要:
      Impulse Current Method(ICM) is limited by the sophisticated test waveforms and the lack of automatic data processing algorithm. Aiming at the problem, an automatic ICM using differential directional traveling waves and cross-correlation analysis is proposed. Based on the propagation characteristics of cables, the influence of the attenuation distortion and dispersion distortion on the position of the correlation peak is analyzed. The dispersion distortion in the low frequency band is the main factor that declines the location precision of correlation analysis. A low-cost high-reliability and wide-band directional decoupling method for traveling waves is proposed, using current measurement data of two same linear couplers at both ends of the leading cable which are synchronized with the first pulse. The influence of the difference of current and voltage sensors’ transfer characteristics within wide frequency band is evaded. Simulations show the location errors are no more than 0.7% for non-near-end faults. The experimental result on a power cable is 207.26m, while the real fault distance is 207±1m, with a relative error of no more than 0.61%.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司