陈琳,李哲,孙永全.现场运行环境与电应力对电能表计量误差影响研究[J].电测与仪表,2021,58(7):180-188.
Chen Lin,Li Zhe,Sun Yongquan.Measurement error evolution of electricity meters in field operation under environmental and electrical stresses[J].Electrical Measurement & Instrumentation,2021,58(7):180-188.
现场运行环境与电应力对电能表计量误差影响研究
Measurement error evolution of electricity meters in field operation under environmental and electrical stresses
DOI:10.19753/j.issn1001-1390.2021.07.025
中文关键词:  智能电能表  误差一致性  现场运行环境  电流应力  Eyring模型
英文关键词:Smart electricity meters, error consistency, operation environment, current stress  Eyring model
基金项目:基金项目:山东省技术创新项目(201941001013);国网山东省电力公司科技项目(52063320001Q)
        
作者中文名作者英文名单位
陈琳Chen Lin国网山东省电力公司营销服务中心计量中心
李哲Li Zhe国网山东省电力公司
孙永全Sun Yongquan哈尔滨理工大学传感器与可靠性工程研究所;哈尔滨理工大学传感器与可靠性工程研究所
摘要点击次数: 2072
中文摘要:
      针对智能电能表现场计量的精度问题,利用现场运行数据分析温度、电流、功率因数对批量电能表计量误差及其一致性的影响。基于正态分布计算电能表计量误差的均值和标准差,利用三倍标准差开展计量误差一致性分析。基于正弦函数构建电能表计量误差伴随日历时间的演变规律模型,在分别阐明功率因数和电流应力对电能表计量误差均值和标准差影响的基础上,基于Eyring模型构建环境温度和电应力作用下电能表计量误差响应模型,以阐释温度和电流对电能表计量误差的综合影响。统计分析发现,温度越低、电流越大,电能表计量误差越大。依据研究结果可以补偿电能表计量误差以提高计量结果准确性,同时对进一步优化电能表运维方案,改进设计也具有参考价值。
英文摘要:
      The accuracy of the smart electricity meters was affected by operation conditions, this study focused on the measurement error and consistency of smart electricity meters. The mean and standard deviation of power error were calculated based on the normal distribution, and three times of standard deviation was employed to elaborate the consistency of measurement errors. The evolution model of the measurement error of electricity meters with calendar time was constructed based on a sinusoidal function, and then Eyring model was employed to describe the effects of temperature and current stresses on the evolution behavior of the power error mean value for electricity meters. In terms of the effects of temperature, the mean value of metering power error declines with the increase of temperature and the decrease of the current. The results have reference value for power metering error compensation, optimization of operation and maintenance scheme, and design optimization to improve the consistency and reliability of electricity meters.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司