许磊,郑超,孟洋洋,白树斌,魏佛送,张琪琦.智能变电站二次装置一键式隔离系统研究[J].电测与仪表,2024,61(6):141-147.
XU Lei,ZHENG Chao,MENG Yangyang,BAI Shubin,WEI Fusong,ZHANG Qiqi.Research on one-key isolation system of secondary devices in smart substation[J].Electrical Measurement & Instrumentation,2024,61(6):141-147.
智能变电站二次装置一键式隔离系统研究
Research on one-key isolation system of secondary devices in smart substation
DOI:10.19753/j.issn1001-1390.2024.06.019
中文关键词:  智能变电站  二次装置  虚拟回路  数字化
英文关键词:smart substation, secondary device, virtual circuit, digitalization
基金项目:国家重点研发计划(2017YFB0902800);国家电网公司科技项目(390034734600010)
                 
作者中文名作者英文名单位
许磊XU Lei国网济宁供电公司
郑超ZHENG Chao国网济宁供电公司
孟洋洋MENG Yangyang国网济宁供电公司
白树斌BAI Shubin国网济宁供电公司
魏佛送WEI Fusong国网济宁供电公司
张琪琦ZHANG Qiqi山东网聪信息科技有限公司
摘要点击次数: 494
中文摘要:
      由于通信机制虚拟化及网络化,智能变电站二次回路检修时难以对二次回路进行经济有效隔离。文中建立了智能变电站二次装置一键式隔离系统,并给出系统需要的软件和硬件配置方案。首先介绍了研究理论方法,利用无提取的可扩展标记语言解析方法对智能变电站IEC 61850 SCD配置文件进行快速解耦和分析计算,并把站内检修与改扩建过程中的隔离范围问题转化为图信号处理方法中的事件扩散问题,并通过图信号处理技术实现复杂数据处理算法可视化展示。然后给出了SV链路、GOOSE输出链路、GOOSE接收链路和软压板之间的对应规则,明确检修时隔离的范围。最后,对装置隔离的安全措施序列可视化生成,能够直观地显示二次回路的隔离情况,协助现场人员进行检修工作。
英文摘要:
      Due to the virtualization and networking of the communication mechanism, it is difficult to economically and effectively isolate the secondary circuit during the maintenance of the secondary circuit in the smart substation. In this paper, a one-key isolation system for secondary devices of smart substations is established, and the software and hardware configuration schemes required by the system are given. Firstly, it introduces the research theory method, utilizes the non-extractable extensible markup language analysis method to quickly decouple and analyze and calculate the IEC 61850 SCD configuration file of the smart substation, and converts the isolation range problem in the process of maintenance and reconstruction of the station into event diffusion problem in graphic signal processing, and the visualization display of complex data processing algorithms is realized through graph signal processing technology. Then, the corresponding rules between SV link, GOOSE output link, GOOSE receiving link and soft pressure plate are given to clarify the range of isolation during maintenance. Finally, the visual generation of the sequence of safety measures for device isolation can visually display the isolation of the secondary circuit and assist on-site personnel to carry out maintenance work.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司