张淞珲,马超俊,徐盈盈,李红斌,张荣浩,李志民.基于标签信息流的变电站电缆走向识别方法[J].电测与仪表,2024,61(6):167-172,180.
ZHANG Songhui,MA Chaojun,XU Yingyin,LI Hongbin,ZHANG Ronghao,LI Zhimin.Identification method of cable orientation in substations based on label information flow[J].Electrical Measurement & Instrumentation,2024,61(6):167-172,180.
基于标签信息流的变电站电缆走向识别方法
Identification method of cable orientation in substations based on label information flow
DOI:10.19753/j.issn1001-1390.2024.06.022
中文关键词:  电缆在线识别  注入法  CDMA  Walsh码
英文关键词:cable online identification, injection method, CDMA, Walsh code
基金项目:国家自然科学基金智能电网联合基金(U1866201)
                 
作者中文名作者英文名单位
张淞珲ZHANG Songhui国网山东省电力公司营销服务中心(计量中心)
马超俊MA Chaojun华中科技大学电气与电子工程学院
徐盈盈XU Yingyin华中科技大学电气与电子工程学院
李红斌LI Hongbin华中科技大学电气与电子工程学院
张荣浩ZHANG Ronghao国网山东省电力公司聊城供电公司
李志民LI Zhimin国网山东省电力公司德州供电公司
摘要点击次数: 501
中文摘要:
      电缆走向识别是电缆检修和施工中的重要一环,其识别的准确性直接影响人身和设备的安全。文章提出了一种基于标签信息流的变电站电缆走向识别方法,依据预定区域内变电站数量确定各变电站的标签码,将调制后包含变电站信息的标签信号通过各变电站接地网注入到出线电缆的屏蔽层上进行传输,在待测电缆侧检测信号后,将各变电站注入的标签信号与检测信号作相关运算,相关结果峰值最高的变电站即为待测电缆首尾所连接的变电站,从而在无需知晓电缆首尾连接归属的情况下实现电缆的走向识别。实验测试结果验证了基于标签信息流的变电站电缆走向识别方法的准确性和高效性。
英文摘要:
      Cable orientation recognition is an important part of cable maintenance and construction. The accuracy of identification directly affects the safety of personnel and equipment. This paper proposes an identification method of cable orientation in substations based on label information flow. The label code of each substation is determined according to the number of substations in a predetermined area, and the modulated label signal containing substation information is injected into the shielding layer of the outgoing cable through the grounding network of each substation. After the signal is detected on the cable under test, the tag signal injected by each substation is correlated with the detection signal. The substation with the highest correlation result is the substation connected to the end of the cable under test, so the orientation of the cable can be identified without knowing the attribution of the beginning and end of the cable. The experimental test results verify the accuracy and efficiency of the identification method of the cable direction of the substation based on the label information flow.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司