• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
王红标,粟时平,胡亚杰,欧阳振宇.含电动汽车快速充电站配电网的暂态电能质量特性研究[J].电测与仪表,2024,61(6):159-166.
WANG Hongbiao,SU Shiping,HU Yajie,OUYANG Zhenyu.Study on transient power quality characteristics of distribution network with EV quick charging stations[J].Electrical Measurement & Instrumentation,2024,61(6):159-166.
含电动汽车快速充电站配电网的暂态电能质量特性研究
Study on transient power quality characteristics of distribution network with EV quick charging stations
DOI:10.19753/j.issn1001-1390.2024.06.021
中文关键词:  快速充电站  配电网  电压暂降  电磁暂态  分布参数  等效模型
英文关键词:quick charging station, distribution network, voltage sag, electromagnetic transient, distribution parameter, equivalent model
基金项目:国家自然科学基金资助项目(51708194);湖南省教育厅科学研究重点项目(18A120)
           
作者中文名作者英文名单位
王红标WANG Hongbiao长沙理工大学电气与信息工程学院
粟时平SU Shiping长沙理工大学电气与信息工程学院
胡亚杰HU Yajie长沙理工大学电气与信息工程学院
欧阳振宇OUYANG Zhenyu长沙理工大学电气与信息工程学院
摘要点击次数: 575
中文摘要:
      规模化电动汽车作为间歇性、冲击性负荷接入配电网,会对含电动汽车快速充电站配电网的暂态电能质量产生直接影响。论文主要对规模化电动汽车接入配电网产生的电压暂降、电磁暂态等暂态电能质量问题进行分析。首先对含电动汽车快速充电站的配电网进行建模,其次建立了基于变压器模型的电压暂降模型和基于分布参数等效模型的电磁暂态分析模型。理论分析了快速充电站接入配电网产生暂态电能质量问题,模型能够提高暂态仿真速度及准确性。通过仿真分析验证了快速充电站在正常投切和发生故障时产生的暂态电能质量问题。
英文摘要:
      Large-scale electric vehicles, as intermittent and impact loads, are connected to the distribution network, which will have a direct impact on the transient power quality of the distribution network with quick charging stations of electric vehicles. This paper mainly analyzes the transient power quality problems such as voltage sag and electromagnetic transient caused by large-scale electric vehicles connected to the distribution network. Firstly, the distribution network with EV quick charging stations is modeled. Secondly, the voltage sag model based on the transformer model and the electromagnetic transient analysis model based on the distributed parameter equivalent model are established. The transient power quality problem caused by the connection of quick charging station to distribution network is analyzed theoretically. The model can improve the speed and accuracy of transient simulation. The transient power quality problems in the normal switching and fault of the quick charging station are verified by simulation analysis.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司