• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
李宾宾,张竹,黄杰,张孟鹃,朱胜龙,马亚彬.基于主元-分形理论的电子式电压互感器计量误差自主辨识方法研究[J].电测与仪表,2024,61(10):82-87.
Li Binbin,Zhang Zhu,Huang Jie,Zhang Menjuan,Zhu Shenglong,Ma Yabin.Research on the autonomous identification method of the metering error of the electronic voltage transformer based on principal component-fractal theory[J].Electrical Measurement & Instrumentation,2024,61(10):82-87.
基于主元-分形理论的电子式电压互感器计量误差自主辨识方法研究
Research on the autonomous identification method of the metering error of the electronic voltage transformer based on principal component-fractal theory
DOI:10.19753/j.issn1001-1390.2024.10.011
中文关键词:  电子式互感器  计量误差  主元分析  分形理论  自主辨识
英文关键词:electronic voltage transformer, metering error, principal component analysis, fractal theory, autonomous identification
基金项目:国家电网公司科技项目(SGAHDK00FZJS2100058)
                 
作者中文名作者英文名单位
李宾宾Li Binbin国网安徽省电力有限公司电力科学研究院
张竹Zhang Zhu合肥工业大学
黄杰Huang Jie国网安徽省电力有限公司
张孟鹃Zhang Menjuan合肥工业大学
朱胜龙Zhu Shenglong国网安徽省电力有限公司电力科学研究院
马亚彬Ma Yabin国网安徽省电力有限公司电力科学研究院
摘要点击次数: 376
中文摘要:
      电子式电压互感器(EVT)由大量的电子单元组成,易受变电站复杂运行环境的影响,计量误差的长期稳定性较差。常规检测方法是定期与标准互感器比对校准,属于一种设备状态的抽样检测方法,无法评估EVT的计量数据对节点电能累积作用的影响。针对这一问题,文章基于电力系统节点三相对称的运行特性,通过对三相EVT的计量数据进行主元分形,在残差子分量中建立平方预测方差SPE统计量实现了EVT计量误差的自检测;通过计算EVT运行过程中SPE统计量的分形维数,实现了EVT计量误差劣化形式的自主辨识。研究成果有利于推动EVT的状态检测由定期检测发展为按需检测。
英文摘要:
      Electronic voltage transformer (EVT) is composed of a large number of electronic units, which is easy to fall in fault under the influence of the complex operation environment of substation. The long-term stability of its metering error is poor. The conventional detection method is to compare and calibrate with the standard transformer regularly. It is a sampling inspection method for EVT, and it is unable to evaluate the impact of EVT metering data on node power accumulation. To solve this problem, firstly, based on the three-phase symmetrical operation characteristics of power system nodes, the metering data of three-phase EVT are analyzed by principal component analysis, and SPE statistics are established in the residual subspace to realize the self-detection of EVT metering error. Secondly, the autonomous identification of EVT measurement error degradation form is realized by calculating the fractal dimension of SPE statistics during EVT operation. The research results are helpful to promote the development of EVT state detection from regular detection to on-demand detection.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司