• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
马爱清,毕永翔,陈鑫涛,谢伟强.特高压交直流输电线路带电作业安全防护及碳减排效应分析[J].电测与仪表,2024,61(8):47-54.
MA Aiqing,BI Yongxiang,CHEN Xintao,XIE Weiqiang.Analysis on safety protection and carbon emission reduction effect of UHV AC/DC transmission line live working[J].Electrical Measurement & Instrumentation,2024,61(8):47-54.
特高压交直流输电线路带电作业安全防护及碳减排效应分析
Analysis on safety protection and carbon emission reduction effect of UHV AC/DC transmission line live working
DOI:10.19753/j.issn1001-1390.2024.08.006
中文关键词:  特高压输电线路  交直流同廊道  体表混合电场  电位转移电流  暂态能量  碳减排
英文关键词:UHV transmission lines, AC/DC corridor, mixed electric field on body surface, potential transfer current, transient energy, carbon emission reduction
基金项目:上海市自然科学基金(19ZR1420600)、上海绿色能源并网工程技术研究中心(13DZ2251900)
           
作者中文名作者英文名单位
马爱清MA Aiqing上海电力大学 电气工程学院,上海 200090
毕永翔BI Yongxiang上海电力大学 电气工程学院,上海 200090
陈鑫涛CHEN Xintao上海电力大学 电气工程学院,上海 200090
谢伟强XIE Weiqiang上海电力大学 电气工程学院,上海 200090
摘要点击次数: 397
中文摘要:
      特高压(ultra high voltage, UHV)交流与直流线路同廊道运行时带电作业区域电压高、场强大,交直流混合电场比单一电场更为复杂。为确保作业人员安全,结合实际±1100kV直流和1000kV交流线路,建立了包含输电导线、杆塔及带电作业人员的三维计算模型,通过分析开展带电作业时人员的体表混合场强、电位转移电流及暂态能量,对作业人员安全防护进行研究。结果表明:随着作业人员不断接近直流线路,体表场强受交流线路影响越明显,最高可使作业人员体表场强增大约9%,达到1920kV/m;交流线路的存在将导致电位转移电流增长约7%,但对暂态能量影响较小。通过对特高压线路不停电检修所减少的碳排放量进行进一步计算,验证了特高压带电作业对减少碳排放具有促进作用。
英文摘要:
      When UHV AC and DC lines run in the same corridor, the voltage in the live working area is high and the field is strong. The AC/DC mixed electric field is more complex than a single electric field. In order to ensure the safety of workers, combined with the actual ±1 100kV DC and 1000kV AC lines, a three-dimensional calculation model including transmission lines, towers and live working personnel is established in this paper. Through the analysis of the mixed field strength, potential transfer current and transient energy on the body surface of workers during live working, the safety protection of workers is studied. The results show that as the operators approach the DC line, the field strength on the body surface is more obviously affected by the AC line, which can increase the field strength on the body surface of the operators by about 9% to 1920kV/m at most. The existence of AC line will increase the potential transfer current by about 7%, but has little effect on transient energy. Through the further calculation of carbon emissions reduced by non-power outage maintenance of UHV lines, it is verified that UHV live working has a promoting effect on reducing carbon emissions.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司