王华昕,刘健,邹龙,麻宁杰,邓祥力.新型电力系统下低压直流配网的接地故障保护方法[J].电测与仪表,2024,61(10):144-152.
Wang Huaxin,Liu Jian,Zou Long,Ma Ningjie,Deng Xiangli.Grounding fault protection method for low-voltage DC distribution network under novel power system[J].Electrical Measurement & Instrumentation,2024,61(10):144-152.
新型电力系统下低压直流配网的接地故障保护方法
Grounding fault protection method for low-voltage DC distribution network under novel power system
DOI:10.19753/j.issn1001-1390.2024.10.019
中文关键词:  新型电力系统  低压直流配网  旁路投切  分级保护
英文关键词:novel power system, low voltage DC distribution network, bypass switching, hierarchical protection
基金项目:国家自然科学基金资助项目( 51777119)
              
作者中文名作者英文名单位
王华昕Wang Huaxin上海电力大学
刘健Liu Jian上海电力大学
邹龙Zou Long国网阜阳供电公司
麻宁杰Ma Ningjie上海电力大学
邓祥力Deng Xiangli上海电力大学
摘要点击次数: 424
中文摘要:
      电力系统低碳转型,构建安全高效和灵活可靠的配电网为基础的新型电力系统将对我国“碳达峰、碳中和”目标的实现起到关键作用。文中以低压直流(low voltage direct current,LVDC)配网系统为研究对象,针对配电网低压侧的接地故障问题,提出了一种采用IGBT构造投切旁路的人体保护方法。文中建立接地故障等效模型并进行理论分析,通过故障阈值识别判据产生保护人体的投切旁路信号,并对不同类型的接地故障进行区分,考虑多支路故障情况对旁路投切保护判据的影响,将故障值范围进行划分,进一步提出了旁路投切的分级保护方案,搭建实物模型对保护方法进行验证。实验结果表明所提保护方法能保护人体安全,具有灵敏性好,安全可控的优点,能显著提高配网系统的运行稳定性。
英文摘要:
      The low-carbon transformation and the construction of novel power system based on a safe, efficient, flexible and reliable distribution network will play a pivotal role in the realization of "carbon peaking and carbon neutrality" goals. This paper takes the low voltage direct current (LVDC) distribution network system as the research object, a human body protection method using insulated gate bipolar transistor (IGBT) is proposed to construct a switching bypass for the grounding fault problem on the low voltage side of the distribution network. The grounding fault equivalent model is established for theoretical analysis, the switching bypass signal protecting human body is generated through the fault threshold identification criterion, and different types of grounding faults are distinguished. Considering the influence of multi-branch fault conditions on the protection criterion of bypass switching, the fault value range is divided, and the hierarchical protection scheme of bypass switching is further proposed. A physical model is built to verify the protection method. The experimental results show that the proposed protection method can protect human safety with the advantages of good sensitivity, safety and controllability, also can significantly improve the operation stability of the distribution network system.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司