郭森林,朱江淼,耿西西,潘仙林,石照民,金涛.基于参考电流增量法的感应分流器校验方法[J].电测与仪表,2024,61(10):175-180.
Guo Senlin,Zhu Jangmiao,Geng Xixi,Pan Xianlin,Shi Zhaomin,Jin Tao.Calibration of inductive current divider based on reference current increment method[J].Electrical Measurement & Instrumentation,2024,61(10):175-180.
基于参考电流增量法的感应分流器校验方法
Calibration of inductive current divider based on reference current increment method
DOI:10.19753/j.issn1001-1390.2024.10.023
中文关键词:  双级感应分流器  参考电流增量法  电流比例  容性泄漏
英文关键词:two-stage inductive current divider, reference current increment method, current proportion, capacitive leakage
基金项目:国家自然科学基金资助项目( 62101521)
                 
作者中文名作者英文名单位
郭森林Guo Senlin北京工业大学
朱江淼Zhu Jangmiao北京工业大学
耿西西Geng Xixi中国计量科学研究院
潘仙林Pan Xianlin中国计量科学研究院
石照民Shi Zhaomin中国计量科学研究院
金涛Jin Tao中国计量大学
摘要点击次数: 378
中文摘要:
      感应分流器具有高准确度和高稳定性的电流比例,在电流互感器检定领域有着广泛的应用。文中提出了一种基于参考电流增量法原理的感应式分流器校验方法,文中介绍了参考电流增量法的基本原理;分析了参考电流互感器和差值电流测量线路的设计原理;搭建了感应分流器自校验的实验线路;对研制的双级感应分流器在50 Hz~1 kHz频率范围进行了校验,并对校验结果进行了不确定度分析。实验结果表明,在50 Hz~1 kHz频率范围内,双级感应分流器比值差测量合成标准不确定度优于5×10-8 A/A,相位差测量合成标准不确定度优于1×10-7 rad。
英文摘要:
      Inductive current divider has high accuracy and high stability of current ratio, which is widely used in the verification of current transformer and other fields. In this paper, a method for calibrating inductive current divider based on the principle of reference current increment method is proposed, and the basic principle of reference current increment method is introduced; the design principles of reference current transformer and differential current measurement circuit are analyzed; the experimental circuit for the self-calibration of the inductive current divider is built; the developed two-stage inductive current divider is calibrated in the frequency range of 50 Hz~1 kHz, and the uncertainty of the calibration result is analyzed. The experimental results show that, in the frequency range of 50 Hz~1 kHz, the measurement synthetic standard uncertainty of the ratio difference of the two-stage inductive current divider is better than 5×10-8 A/A, and the measurement synthetic standard uncertainty of the phase difference is better than 1×10-7 rad.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司