• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
高雨翔,蔡奇新,徐文林.基于牵引负荷负序功率潮流计算及电能计量方式研究[J].电测与仪表,2023,60(1):193-200.
Gao Yuxiang,Cai Qixin,Xu Wenlin.Study on negative sequence power flow calculation and electric energy metering mode of traction load[J].Electrical Measurement & Instrumentation,2023,60(1):193-200.
基于牵引负荷负序功率潮流计算及电能计量方式研究
Study on negative sequence power flow calculation and electric energy metering mode of traction load
DOI:10.19753/j28ssn1001-1390.2023.01.001
中文关键词:  牵引负荷  负序功率  潮流计算  电能计量方式  相关性  功率因数
英文关键词:traction load, negative sequence power, power flow calculation, electric energy metering mode, correlation, power factor
基金项目:国家重点研发计划“科技助力经济2020”重点专项《城区永华负荷特征感知能力提升机扩展应用》资助项目(2020YFF0426410)
        
作者中文名作者英文名单位
高雨翔Gao Yuxiang国网江苏省电力有限公司营销服务中心, 南京 210019
蔡奇新Cai Qixin国网江苏省电力有限公司营销服务中心, 南京 210019
徐文林Xu Wenlin国网湖南省电力有限公司,长沙 410000
摘要点击次数: 1896
中文摘要:
      针对不对称的牵引负荷会引起负序功率潮流,直接影响电能计量结果的可靠性和准确性,文章提出了一种牵引负荷负序功率潮流计算及电能计量的调整方法。分析了牵引负荷负序功率分布情况,将分析结果结合牵引负荷的相关性,采用Copula理论构建牵引负荷负序功率潮流分析模型,计算牵引负荷正序功率的潮流结果以及分布和流向;依据计算结果分析牵引负荷负序功率潮流对电能计量的影响,提出基于功率因数理论电能计量调整方案。测试结果表明,文中方法具备良好的负序功率潮流计算效果,与实际结果之间的最大差值均低于0.000 6,功率因数的取值为0.7时,能够合理、可靠地完成电能计量,保证计量结果的准确性。
英文摘要:
      Asymmetric traction load will cause negative sequence power flow and directly affect the reliability and accuracy of electric energy metering results. Therefore, this paper studies the calculation of traction load negative sequence power flow and the adjustment method of electric energy metering. It analyzes the negative sequence power distribution of the traction load, combining the analysis results with the correlation of the traction load, adopts Copula theory to construct a traction load negative sequence power flow analysis model, and calculates the power flow results, distribution and flow direction of the positive sequence power of the traction load. According to the calculation results, the influence of negative sequence power flow of traction load on electric energy metering is analyzed, and an electric energy metering adjustment scheme based on power factor theory is proposed. Finally, the test results show that the method proposed in this paper has a good calculation effect of negative sequence power flow, and the maximum difference between the actual results is less than 0.000 6, and the value of the power factor is 0.7, which can complete the electric energy metering reasonably and reliably, and ensure the accuracy of the metering result.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司