刘永光,谭煌,李志鹏.一种基于电能表误差和窃电分析的线损分层定位方法[J].电测与仪表,2022,59(9):188-194.
Liu yong guang,Tan huang,Li zhipeng.A hierarchical line loss locating method based on the analysis of power meter error and stolen electricity[J].Electrical Measurement & Instrumentation,2022,59(9):188-194.
一种基于电能表误差和窃电分析的线损分层定位方法
A hierarchical line loss locating method based on the analysis of power meter error and stolen electricity
DOI:10.19753/j.issn1001-1390.2002.09.026
中文关键词:  线损治理  线损率  理论线损  统计线损  窃电分析
英文关键词:line loss management, line loss rate, The theory line loss, The statistical line loss, Power analysis
基金项目:国网科技项目 2100/2022-55016B
        
作者中文名作者英文名单位
刘永光Liu yong guang河南许继仪表有限公司
谭煌Tan huang中国电力科学研究院有限公司
李志鹏Li zhipeng河南许继仪表有限公司
摘要点击次数: 1392
中文摘要:
      针对低压台区线损治理周期长,高损点定位不准确等问题,提出了一种基于电能表误差和窃电分析的线损分层定位方法。该方法首先在传统线损分层定位方法的基础上,引入理论线损计算方法,构建了基于基尔霍夫定律的台区线损分层计算模型,实现线损的分层计算,确定高损范围,然后采用电能表误差分析模型,在高损范围内筛查出误差异常电能表,实现台区高损点定位;最后设计电能表窃电分析方法,通过告警事件挖掘与窃电行为相关的频繁项集,进一步对高损点进行验证,并确定其高损原因。该方法采用50个台区的实际数据进行验证,台区线损分层计算模型准确率为100%,电能表误差分析计算模型的准确率为88.5%,电能表窃电分析模型准确率为92%。
英文摘要:
      Aiming at the problems such as long period of line loss control and inaccurate location of high loss point in low voltage station area, a method of line loss stratified location based on power meter error and power stealing analysis is proposed. This method firstly on the basis of traditional line loss layered locating methods, the introduction of theoretical line loss calculation method, constructed based on the kirchhoff's law courts, a layered model for the line loss, realization of line loss layered calculation, determine the scope of the high loss, and then USES the error analysis model of watt-hour meter, within the scope of the high loss of screening out the error of abnormal watt-hour meter, realize area high loss point positioning; Finally, the analysis method of electricity stealing is designed, and the frequent item set related to electricity stealing behavior is mined through alarm events to further verify the high loss point and determine the cause of high loss. The actual data of 50 stations were used to verify the method. The accuracy of the stratified calculation model of line loss in the stations was 100%, the accuracy of the calculation model of power meter error analysis was 88.5%, and the accuracy of the analysis model of power meter stealing was 92%.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司