缪惠宇,史明明,费骏韬,张宸宇.计及综合能源系统接入影响的配电网可靠性评估方法[J].电测与仪表,2022,59(10):23-31.
Miao Huiyu,Shi Mingming,Fei Juntao,Zhang Chenyu.Reliability assessment method of distribution network considering the impact of integrated energy system access[J].Electrical Measurement & Instrumentation,2022,59(10):23-31.
计及综合能源系统接入影响的配电网可靠性评估方法
Reliability assessment method of distribution network considering the impact of integrated energy system access
DOI:DOI: 10.19753/j.issn1001-1390.2022.10.004
中文关键词:  综合能源系统  最优负荷削减  配电网可靠性  目标级联法  马尔科夫链蒙特卡洛
英文关键词:integrated energy system, optimal load reduction, distribution network reliability, analysis target cascading method, Markov chain Monte Carlo
基金项目:国网江苏省电力有限公司科技项目(J2021149)
           
作者中文名作者英文名单位
缪惠宇Miao Huiyu国网江苏省电力有限公司电力科学研究院
史明明Shi Mingming国网江苏省电力有限公司电力科学研究院
费骏韬Fei Juntao国网江苏省电力有限公司电力科学研究院
张宸宇Zhang Chenyu国网江苏省电力有限公司电力科学研究院
摘要点击次数: 1768
中文摘要:
      配电网与综合能源系统(Integrated Energy System, IES)的互联运行是未来配电网重要的发展方向,这将对二者供能的可靠性产生深刻影响。为更加准确地评估配电网可靠性,提出一种计及IES接入影响的配电网可靠性评估方法。文中对IES-配电网联合系统建模,分别建立IES和配电网的最优负荷削减模型;然后,采用目标级联法(Analysis Target Cascading, ATC)分布式求解联合系统的最优负荷削减问题,基于马尔科夫链蒙特卡洛,计算IES-配电网联合系统的可靠性指标,在多种运行场景下对改进的IEEE RBTS-BUS6系统进行可靠性评估。算例结果表明,在合理的运行策略下,IES接入后可以大幅改善配电网可靠性,且热电联产机组对配电网可靠性的重要度最高。
英文摘要:
      The interconnection operation between distribution network (DN) and integrated energy system (IES) is an important development direction, which has a profound impact on the reliability of energy supply. In order to evaluate the reliability of DN more accurately, a reliability assessment method of DN considering the impact of IES access is proposed. Firstly, the IES-DN joint system is modeled, and the optimal load reduction model between IES and distribution network is established respectively. Secondly, the optimal load reduction models of IES and DN are established respectively, the analysis target cascading (ATC) method is used to solve the optimal load reduction problem of the joint system and the reliability index of IES-DN joint system is calculated based on Markov chain Monte Carlo, the reliability of the improved IEEE RBTS-BUS6 system is evaluated under various operation scenarios. The results show that under the reasonable operation strategy, the reliability of DN can be greatly improved after IES access and the cogeneration unit has the highest importance to the reliability of DN.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司