胡顺财,李京,陈平,刘洋,周福涛,陈浩浩.基于分布式行波的混合线路故障测距算法研究[J].电测与仪表,2025,62(2):188-194.
HU Shuncai,LI Jing,CHEN Ping,LIU Yang,ZHOU Futao,CHEN Haohao.Research on fault location algorithm of hybrid line based on distributed traveling wave[J].Electrical Measurement & Instrumentation,2025,62(2):188-194.
基于分布式行波的混合线路故障测距算法研究
Research on fault location algorithm of hybrid line based on distributed traveling wave
DOI:10.19753/j.issn1001-1390.2025.02.023
中文关键词:  混合输电线路  分布式故障测距  奇异值分解  故障区段识别  在线波速测量
英文关键词:hybrid transmission line, distributed fault location, singular value decomposition (SVD), fault section identification, online wave speed measurement
基金项目:国家重点研发计划项目(2017YFB0902800);国家电网公司科技项目(52094017003D)
                 
作者中文名作者英文名单位
胡顺财HU Shuncai山东理工大学 电气与电子工程学院
李京LI Jing山东理工大学 电气与电子工程学院
陈平CHEN Ping山东理工大学 电气与电子工程学院
刘洋LIU Yang山东理工大学 电气与电子工程学院
周福涛ZHOU Futao山东理工大学 电气与电子工程学院
陈浩浩CHEN Haohao山东理工大学 电气与电子工程学院
摘要点击次数: 300
中文摘要:
      线缆混合输电线路故障时将出现更加复杂的行波折反射现象,对于故障测距带来不小的难度。为解决此类问题,根据电缆与架空线各自的结构、特性的不同,在输电线路上安装分布式的行波检测装置将线路分成若干区间。应用皮尔逊相关系数的相关性原理,确定故障发生的区间。通过详细的公式推导,抵消掉波速对测距精度的影响,利用第二个SVD(singular value decomposition)分量标定出信号奇异点的脉冲模极大值,推导出分区间不含波速的混合线路故障定位算法。通过PSCAD仿真及MATLAB数据处理结果表明,与常规的单双端测距法应用于线缆组成的混合输电线路相比,可进一步提高测距精度。
英文摘要:
      When the cable hybrid transmission line fails, more complex traveling wave refraction and reflection will appear, which brings great difficulty to fault location. In order to solve such problems, according to the different structures and characteristics of cables and overhead lines, the distributed traveling wave detection devices are installed on transmission lines to divide the lines into several sections. The correlation principle of Pearson′s correlation coefficient is applied to determine the interval of fault occurrence. Through detailed formula derivation, the influence of the wave speed on the ranging accuracy is canceled, and the second singular value decomposition (SVD) component is used to demarcate the maximum value of the pulse mode of the singular point of the signal, and the fault location algorithm for hybrid lines without wave speed between sub-divisions is deduced. The results of PSCAD simulation and MATLAB data processing show that compared with the conventional single and double-terminal location method applied to the hybrid transmission line composed of cables, the location accuracy can be further improved.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司