付铭,朱明,梅杰,张静,肖黎,张宗喜.基于多元振动序列共性特征的电抗器故障诊断[J].电测与仪表,2025,62(3):198-207.
FU Ming,ZHU Ming,MEI Jie,ZHANG Jing,XIAO Li,ZHANG Zongxi.Reactor fault diagnosis based on common feature of multivariate vibration sequences[J].Electrical Measurement & Instrumentation,2025,62(3):198-207.
基于多元振动序列共性特征的电抗器故障诊断
Reactor fault diagnosis based on common feature of multivariate vibration sequences
DOI:10.19753/j.issn1001-1390.2025.03.024
中文关键词:  高压并联电抗器  故障诊断  特征选择  递归特征消除算法  遗传算法
英文关键词:high voltage shunt reactor, fault diagnosis, feature selection, SVM-RFE, GA
基金项目:国家电网公司科技项目(52199919000A)
                 
作者中文名作者英文名单位
付铭FU Ming华中科技大学 电子信息与通信学院,武汉 430074
朱明ZHU Ming华中科技大学 电子信息与通信学院,武汉 430074
梅杰MEI Jie华中科技大学 电子信息与通信学院
张静ZHANG Jing2.南瑞集团(国网电力科学研究院)有限公司, 南京 211106; 3.国网电力科学研究院武汉南瑞有限责任公司,武汉 430074
肖黎XIAO Li2.南瑞集团(国网电力科学研究院)有限公司, 南京 211106; 3.国网电力科学研究院武汉南瑞有限责任公司,武汉 430074
张宗喜ZHANG Zongxi国网四川省电力公司电力科学研究院, 成都 610041
摘要点击次数: 297
中文摘要:
      针对当前特征选择算法只适用于单元振动序列的限制,提出了结合基于支持向量机递归特征消除算法(support vector machine recursive feature elimination algorithm, SVM-RFE)和遗传算法(genetic algorithm, GA)的多元振动序列特征选择算法SVM-RFE-GA。以某220 kV高压并联电抗器为研究对象搭建了机械故障模拟平台,设置了5种不同设备状态,在其表面24个采样位置采集不同设备状态的多元振动序列。实验从时域、频域和时频域出发构建特征池,利用SVM-RFE对单元振动序列中各个特征进行重要性排序和初步筛选,并记录每个位置的最高故障诊断准确率。再对初步筛选出的特征利用GA算法进一步优化选择,选出多元振动序列中具有最高准确率且数量最少的特征组合。实验结果表明,该方法可以选出多元振动序列的共性特征组合,同时该组合可以确保电抗器故障诊断准确率最高且特征数目最少。
英文摘要:
      Aiming at the limitation that current feature selection algorithms are only available for univariate vibration sequence, this paper proposes a multivariate vibration sequences feature selection algorithm named SVM-RFE-GA based on support vector machine recursive feature elimination algorithm (SVM-RFE) and genetic algorithm (GA). Taking a 220 kV high voltage shunt reactor as the research object, we build a mechanical fault simulation platform, set up 5 kinds of equipment states and collect multivariate vibration sequences of different equipment states at 24 sampling positions on its surface. We construct the feature pool from the time domain, frequency domain and time-frequency domain. For single vibration sequences, we rank the features and select features preliminarily by SVM-RFE. Then, the preliminarily select features are further optimized by GA algorithm to select the feature combination with the highest accuracy and the least number. The experimental result shows that the proposed method can select the common feature combination of multivariate vibration sequences, and the combination can ensure the highest fault diagnosis accuracy and the minimum number of features.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 社长及主编
    • 期刊荣誉
  • 编委会
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司