张玥玮,韩民晓,张明洋.电网故障下直驱风电机组预测控制策略研究[J].电测与仪表,2025,62(4):157-165.
ZHANG Yuewei,HAN Mnxiao,ZHANG Mingyang.Research on predictive control strategies for direct-drive wind turbines under power grid fault[J].Electrical Measurement & Instrumentation,2025,62(4):157-165.
电网故障下直驱风电机组预测控制策略研究
Research on predictive control strategies for direct-drive wind turbines under power grid fault
DOI:10.19753/j.issn1001-1390.2025.04.019
中文关键词:  风电并网  模型预测控制  故障穿越  无功支撑  正负分量提取
英文关键词:wind power grid connection, model predictive control, fault ride-through, reactive power support, extraction of positive and negative sequence components
基金项目:国家重点研发计划(2021YFB2400500)
        
作者中文名作者英文名单位
张玥玮ZHANG YueweiSchool of Electrical and Electronic Engineering, North China Electric Power University
韩民晓HAN Mnxiao华北电力大学
张明洋ZHANG Mingyang华北电力大学
摘要点击次数: 185
中文摘要:
      电网发生故障时,风电机组的有功/无功动态特性是影响机组穿越特性及并网点电压的关键因素。为解决传统比例-积分(proportional-integral, PI)控制跟踪速度较慢及控制回路设计复杂的问题,提出了基于模型预测控制(model predictive control, MPC)的低电压穿越控制策略。采用MPC代替网侧换流器控制回路中的电流内环来提升故障穿越时的暂态特性,在电压不对称跌落情况下,结合最新入网标准推导指令值并设计了更为简洁的控制回路,在MATLAB/Simulink平台上分别进行了对称故障、不对称故障两组仿真验证:对称故障情况下,对比传统控制、模糊PI控制(fuzzy PI control),验证了所提控制策略具有更好暂态特性,能够更好地为应对电网故障提供无功支撑。不对称故障情况下,通过仿真验证所提控制策略能够有效降低三相电压不平衡度。
英文摘要:
      The active/reactive dynamic characteristics of the wind turbine are the key factors affecting the fault ride-through characteristics and the grid-connected voltage when a fault occurs in the power grid. To solve the problems of slow tracking speed and complex control loop design of traditional proportional-integral(PI) control, a model predictive control (MPC)-based LVRT control strategy is proposed. Firstly, MPC is used instead of the current inner-loop in the control loop of the network-side converter to improve the transient characteristics during fault ride-through. Then, in the case of asymmetric voltage dips, a more concise control loop is designed by combining the latest grid entry standards to derive the command values. Finally, two sets of simulations are carried out on MATLAB/Simulink platform to verify the symmetrical and asymmetrical faults. In the case of symmetrical faults, it is verified that the proposed control strategy has better transient characteristics and can better cope with grid faults and provide reactive power support compared with the traditional control and fuzzy PI control. In the case of asymmetric faults, the proposed control strategy is verified to be effective in reducing the three-phase voltage unbalance through simulation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司