张尚然,汤亚芳,袁旭峰.基于系统结构的智能变电站继电保护可靠性分析[J].电测与仪表,2024,61(12):164-170.
ZHANG Shangran,TANG Yafang,YUAN Xufeng.Reliability analysis of relay protection in intelligent substation based on system structure[J].Electrical Measurement & Instrumentation,2024,61(12):164-170.
基于系统结构的智能变电站继电保护可靠性分析
Reliability analysis of relay protection in intelligent substation based on system structure
DOI:10.19753/j.issn1001-1390.2024.12.020
中文关键词:  智能变电站  继电保护  可靠性分析  系统结构
英文关键词:intelligent substation, relay protection, reliability analysis, system structure
基金项目:国家自然科学基金资助项目(52067004)
        
作者中文名作者英文名单位
张尚然ZHANG Shangran河北省仪器仪表工程技术研究中心,河北 承德 067000
汤亚芳TANG Yafang贵州大学 电气工程学院, 贵阳 550025
袁旭峰YUAN Xufeng贵州大学 电气工程学院, 贵阳 550025
摘要点击次数: 480
中文摘要:
      随着智能变电站的发展与完善,系统结构愈加复杂,多种因素导致智能变电站继电保护系统的可靠性降低,因此对智能变电站继电保护进行可靠性分析变得愈发重要。因可靠性分析的需要,提出一种基于系统结构的智能变电站继电保护可靠性分析的方法。先使用可靠性框图法对智能变电站继电保护系统进行建模,使用联络矩阵法找到网络系统中的最小路集,再引入最小路集不交化法对保护系统的可靠性进行分析,对智能变电站继电保护系统做出基于系统结构的可靠性分析。与现有的传统解析法和模拟法相比,文中所用方法流程清晰,便于查找建模过程中的错误环节。能够清楚地表述系统结构内部各智能元件之间的逻辑关系,便于找到处在继电保护系统中重要位置的元件,使可靠性分析变得简明、直观,且此方法在避免了大量重复运算的同时,又保证了计算结果的精度。
英文摘要:
      With the development and improvement of intelligent substation, the system structure becomes more and more complex. Many factors lead to the reduction of the reliability of intelligent substation relay protection system. Therefore, the reliability analysis of intelligent substation relay protection becomes more and more important. Due to the need of reliability analysis, a method of reliability analysis of intelligent substation relay protection based on system structure is proposed. Firstly, the reliability block diagram method is used to model the relay protection system of intelligent substation, and the contact matrix method is used to find the minimum path set in the network system. Secondly, the minimum path set disjoint method is introduced to analyze the reliability of the protection system, and a reliability analysis of relay protection system in intelligent substation is conducted based on system structure. Compared with the existing traditional analytical method and simulation method, the method proposed in this paper has a clear flow, which is convenient to find the wrong links in the modeling process. It can clearly express the logical relationship between the intelligent components in the system structure, and it is convenient to find the components in the important position of the relay protection system, so that the reliability analysis becomes concise and intuitive, and this method avoids a large number of repeated calculations, and the accuracy of the calculation results is as well as guaranteed.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司