• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
贺云隆,宋晓林,白宇峰,杨东华,邓宏昌,朱洋洋,何晓奎.基于HPLC的智能电能表通信模块状态监测技术研究[J].电测与仪表,2022,59(10):190-200.
Heyunlong,songxiaolin,baiyufeng,yangdonghua,denghongchang,zhuyangyang,hexiaokui.Research on condition monitoring technology of smart electricity meter communication module based on HPLC[J].Electrical Measurement & Instrumentation,2022,59(10):190-200.
基于HPLC的智能电能表通信模块状态监测技术研究
Research on condition monitoring technology of smart electricity meter communication module based on HPLC
DOI:DOI: 10.19753/j.issn1001-1390.2022.10.027
中文关键词:  HPLC  监测装置  SD卡存储  分布式  故障研判
英文关键词:HPLC, monitoring device, SD card storage, distributed, fault research and judgment
基金项目:国网陕西省电力有限公司科技项目(5226YX220003)
                    
作者中文名作者英文名单位
贺云隆Heyunlong国网陕西省电力有限公司营销服务中心(计量中心)
宋晓林songxiaolin国网陕西省电力有限公司营销服务中心(计量中心)
白宇峰baiyufeng国网陕西省电力有限公司
杨东华yangdonghua国网陕西省电力有限公司营销服务中心(计量中心)
邓宏昌denghongchang北京中宸微电子有限公司
朱洋洋zhuyangyang北京中宸微电子有限公司
何晓奎hexiaokui北京中宸微电子有限公司
摘要点击次数: 2561
中文摘要:
      为了准确抓取低压混装台区高速电力线载波(HPLC)模块通信故障原因,提升数据采集成功率,设计了一种基于HPLC技术的智能电能表通信模块状态监测装置。该装置安装于HPLC通信模块和智能电能表或集中器之间,通过载波实时自动监听不同厂家的通信模块运行状态信息、通信报文信息和网络噪声信息等,并将携带全网络统一时标的信息实时写入所带的非易失存储器中,利用软件对存储日志进行自动化解析,按照流程来判别故障原因。将该装置应用于异常台区,精准定位了网络故障原因,提高了数据采集成功率,通过实验验证了其实用性。
英文摘要:
      To accurately grasp the cause of high-speed power line carrier (HPLC) module communication fault in low-voltage mixed loading station area, improve the success rate of data acquisition, a condition monitoring device of smart electricity meter communication module based on HPLC technology is designed. The device is installed between the HPLC communication module and the smart electricity meter or concentrator, which automatically monitors the operation status information, communication message information and network noise information of communication modules from different manufacturers in real time through the carrier wave, the information carrying the unified time scale of the whole network is written into the nonvolatile memory by the device in real time, the software automatically parses storage log and identifies the cause of fault through the process. The device is used in two abnormal stations to accurately locate the cause of network fault and improve the success rate of data acquisition, which verifies its practicability through experiments.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司