李正,陈堂贤,张赟宁,刘双洋,孙培胜.基于ISSA-BiLSTM的多端柔性直流输电线路保护方案[J].电测与仪表,2025,62(4):97-104.
LI Zheng,CHEN Tangxian,ZHANG Yunning,LIU Shuangyang,SUN Peisheng.Protection scheme of flexible MTDC transmission line based on ISSA-BiLSTM[J].Electrical Measurement & Instrumentation,2025,62(4):97-104.
基于ISSA-BiLSTM的多端柔性直流输电线路保护方案
Protection scheme of flexible MTDC transmission line based on ISSA-BiLSTM
DOI:10.19753/j.issn1001-1390.2025.04.012
中文关键词:  多端柔性直流电网  小波变换  麻雀搜索算法  双向长短时记忆网络  故障诊断
英文关键词:multi-terminal flexible DC grid, wavelet transform, sparrow search algorithm, bidirectional long short-term memory network, fault diagnosis
基金项目:国家自然科学基金资助项目(61603212)
              
作者中文名作者英文名单位
李正LI Zheng三峡大学电气与新能源学院
陈堂贤CHEN Tangxian三峡大学电气与新能源学院
张赟宁ZHANG Yunning三峡大学电气与新能源学院
刘双洋LIU Shuangyang中国长江电力股份有限公司
孙培胜SUN Peisheng三峡大学电气与新能源学院
摘要点击次数: 195
中文摘要:
      针对多端柔性直流输电线路保护的耐受过渡电阻能力差、识别准确率低的问题,提出了一种改进麻雀搜索算法(improved sparrow search algorithm,ISSA)与双向长短时记忆网络(bidirectional long short-term memory network, BiLSTM)结合的诊断模型。基于小波变换技术提取输电线路故障的特征作为模型输入量对模型进行训练;利用Sine混沌映射、学习粒子群算法策略、引入高斯扰动项对原始麻雀搜索算法进行改进,利用ISSA对BiLSTM目标超参数进行寻优,使故障诊断精度达到最优。最后基于PSCAD/EMTDC仿真平台搭建了四端柔性直流输电系统模型,验证表明,其故障识别准确率高、耐过渡电阻能力强,满足可靠性与速动性的要求。
英文摘要:
      Aiming at the problems of poor ability to withstand transition resistance and low recognition accuracy of multi-terminal flexible DC transmission line protection, a diagnostic model combining an improved sparrow search algorithm (ISSA) and bidirectional long short-term memory network (BiLSTM) is proposed. Based on wavelet transform technology, the characteristics of transmission line faults are extracted as model input to train the model; the original sparrow search algorithm is improved by using Sine chaotic mapping, learning particle swarm algorithm strategy, and introducing Gaussian disturbance term. And ISSA is used to optimize the target hyperparameters of BiLSTM, so that the fault diagnosis accuracy is optimal. Finally, based on the PSCAD/EMTDC simulation platform, a four-terminal flexible DC transmission system model is built. The verification shows that it has high fault identification accuracy, strong resistance to transition resistance, and meets the requirements of reliability and rapidity.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司