金恩淑,吴宛凝,张弼弘,朱宏,耿梦炜.适用于空载合闸于匝间故障的特高压换流变压器保护新方法[J].电测与仪表,2025,62(5):58-67.
Jin Enshu,Wu Wanning,Zhang Bihong,Zhu Hong,Geng Mengwei.A new protection method for UHV converter transformers suitable for no-load closing andinter-turn faults[J].Electrical Measurement & Instrumentation,2025,62(5):58-67.
适用于空载合闸于匝间故障的特高压换流变压器保护新方法
A new protection method for UHV converter transformers suitable for no-load closing andinter-turn faults
DOI:10.19753/j.issn1001-1390.2025.05.007
中文关键词:  励磁涌流  内部故障  空载合闸于匝间故障  斯皮尔曼系数  零序电流绝对值时间系数
英文关键词:excitation inrush current, internal fault, no-load closing to inter-turn fault, Spearman coefficient, zero-sequence current absolute value time coefficient
基金项目:国家重点研发计划智能电网技术与装备重点专项(2016YFB0900600)
              
作者中文名作者英文名单位
金恩淑Jin Enshu东北电力大学电气工程学院
吴宛凝Wu Wanning东北电力大学电气工程学院
张弼弘Zhang Bihong东北电力大学电气工程学院
朱宏Zhu Hong东北电力大学电气工程学院
耿梦炜Geng Mengwei东北电力大学电气工程学院
摘要点击次数: 96
中文摘要:
      特高压直流输电系统具有较高的电压等级且为交直流混联,他们之间的耦合关系更为密切,换流变压器产生的励磁涌流和故障电流呈现与普通变压器不同的特性,导致传统保护无法正确识别。文章根据斯皮尔曼系数和零序电流绝对值时间系数,提出了一种识别特高压换流变压器励磁涌流的新方法。该方法针对励磁涌流与内部故障绝对值波形前半周波与后半周波趋势相反计算其斯皮尔曼系数,根据斯皮尔曼系数的值构成区分励磁涌流和内部故障的主判据,针对空载合闸于匝间故障时其波形特征具有涌流的特性,将其网侧零序电流绝对值的时间系数作为辅助判据。通过PSCAD/EMTDC软件仿真,结果表明所提方法能够有效区分励磁涌流和内部故障,并能有效避免因空载合闸于匝间故障造成的保护误制动。由此,换流变压器系统的安全性可以得到明显的改善。
英文摘要:
      The ultral high voltage direct current (UHVDC) transmission system has a high voltage level and is a mixed AC and DC connection, which makes the coupling relationship between them more closely, so that the converter transformer has different characteristics from ordinary transformers in the case of excitation inrush current and internal faults, which causes traditional protections cannot be well identified. In this paper, according to the Spearman coefficient and the time coefficient of absolute value of zero-sequence current, a new method for identifying excitation inrush current of UHV converter transformer is proposed. This method first calculates the Spearman coefficient of the absolute value waveforms of the excitation inrush current and the internal fault in the front and back half-week waves. In view of the waveform characteristics of no-load closing with inrush current characteristics under inter-fault, the time coefficient of the absolute value of the zero-sequence current on the grid side is used as the auxiliary criterion. Through PSCAD/EMTDC software simulation, it is proved that the method proposed in this paper can effectively distinguish the excitation inrush current from the internal fault, and can effectively avoid the protection fault braking caused by the no-load closing on the inter-turn fault. Thus, the safety of converter transformer system can get obvious improvement.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司