门强,刘涛,张俊,吴园园,高康平.基于自主可控技术的智能变电站继电保护远程智能测试方法与应用[J].电测与仪表,2025,62(5):185-192.
MenQiang,Liutao,Zhangjun,Wuyuanyuan,Gaokangping.Remote intelligent test method and application of relay protection of smart substation based on autonomous controllable technology[J].Electrical Measurement & Instrumentation,2025,62(5):185-192.
基于自主可控技术的智能变电站继电保护远程智能测试方法与应用
Remote intelligent test method and application of relay protection of smart substation based on autonomous controllable technology
DOI:10.19753/j.issn1001-1390.2025.05.022
中文关键词:  继电保护  自主可控  复杂事件处理算法  远程测试
英文关键词:relay protection, autonomous and controllable, complex event processing algorithms, remote test
基金项目:国家电网科技项目(5226BJ220005 )
              
作者中文名作者英文名单位
门强MenQiang国网陕西省电力有限公司
刘涛Liutao国网陕西省电力有限公司
张俊Zhangjun国网陕西省电力有限公司
吴园园Wuyuanyuan国网陕西省电力有限公司
高康平Gaokangping国网陕西省电力有限公司
摘要点击次数: 114
中文摘要:
      针对智能变电站继电保护装置校验时间远大于计划停电时间、校验工作量大和相关技术人才培养周期长等问题,文中设计了基于自主可控技术的智能变电站继电保护远程智能测试方法。给出了系统的总体构架和网络构架,在不改动站内原有网络与配置的情况下,部署一个或多个专用站内测试终端,接入过程层和站控层;利用自主可控的DL/T 860协议规则、复杂事件处理算法和告警关联分析引擎机制处理继电保护动作过程中产生的告警信息,提出了继电保护远程智能仿真测试流程、“一键式”保护仿真测试技术和保护配置参数的远程测试技术方法,利用智能变电站继电保护远程智能测试方法对采样正确性和二次回路完整性进行了校验。
英文摘要:
      Aiming at the problems that the verification time of relay protection devices in smart substations is much longer than the planned power outage time, the workload of verification is large, and the training period of related technical personnel is long, this paper designs a remote intelligent test method for relay protection of smart substations based on autonomous controllable technology. The overall architecture and network architecture of the system are given. Without changing the original network and configuration in the station, one or more dedicated in-station test terminals are deployed to access the process layer and station control layer. The DL/T 860 protocol rules, complex event processing algorithms and alarm correlation analysis engine mechanism process the alarm information generated during the action of relay protection, and propose the remote intelligent simulation test process of relay protection, "one-click" protection simulation test technology and the remote testing technology and method of protection configuring parameters. The correctness of sampling and the integrity of the secondary circuit are verified by using the remote intelligent test method of relay protection of smart substation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司