黄肖琪,周羽生,周文晴,杨航,刘应杰.基于储能和无功优化的直驱机组海上风电场低电压穿越策略[J].电测与仪表,2024,61(7):57-64.
HUANG Xiaoqi,ZHOU Yusheng,ZHOU Wenqing,YANG Hang,LIU Yingjie.Low Voltage Ride Through Strategy of the D-PMSG Offshore Wind Power Farm based on Energy Storage and Optimized Reactive Power[J].Electrical Measurement & Instrumentation,2024,61(7):57-64.
基于储能和无功优化的直驱机组海上风电场低电压穿越策略
Low Voltage Ride Through Strategy of the D-PMSG Offshore Wind Power Farm based on Energy Storage and Optimized Reactive Power
DOI:10.19753/j.issn1001-1390.2024.07.009
中文关键词:  锂电池储能  海上风电场  低电压穿越  永磁直驱同步发电机  无功优化
英文关键词:lithium battery energy storage  wind power farm  low voltage ride through  direct drive permanent magnet synchronous generator(D-PMSG)  optimized reactive power control
基金项目:国家自然科学基金资助项目(52177015);湖南省教育厅科学研究重点资助项目(19A018)
              
作者中文名作者英文名单位
黄肖琪HUANG Xiaoqi智能电网运行与控制湖南省重点实验室长沙理工大学
周羽生ZHOU Yusheng智能电网运行与控制湖南省重点实验室长沙理工大学
周文晴ZHOU Wenqing智能电网运行与控制湖南省重点实验室长沙理工大学
杨航YANG Hang智能电网运行与控制湖南省重点实验室长沙理工大学
刘应杰LIU Yingjie智能电网运行与控制湖南省重点实验室长沙理工大学
摘要点击次数: 383
中文摘要:
      针对直驱永磁机组海上风电场中的低电压穿越问题,提出了一种基于储能和无功优化控制的低电压穿越控制方案。采用锂电池作为分散式储能设备,吸收故障时刻直流母线上多余功率;同时以网侧变流器输出有功功率、直流母线电压、机端电压作为评价指标,对风电场中各台风电机组低电压穿越能力进行评估,优化控制各台机组的无功出力,从而有效抑制电网故障时机组直流侧电压上升,同时支撑并网点电压恢复。以某海上风电场为例进行仿真分析,仿真结果表明了该方案能显著提高风电场低电压穿越能力。
英文摘要:
      To the problem of low voltage ride through of the permanent magnetive synchronous offshore wind power, a control scheme based on energy storage and reactive power optimization is proposed for the DC link overvoltage problem in the unit grid-connected system. Taking distributed energy storage equipment, using the charging and discharging characteristics of the battery, the superfluous power of the DC bus can be absorbed when takes place a fault. The the active power output of the grid side converter, the DC bus voltage and the generator terminal voltage as the evaluation indexes, the low voltage ride through ability of each unit in the wind farm is evaluated to optimize the control of energy storage and reactive power output of each unit. The DC voltage rise of the unit is effectively suppressed when the grid fault occurs, and the grid voltage is supported. An offshore wind power farm as an example, the simulation results show that this scheme can significantly improve the low voltage ride-through capability of wind farm.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司