郭卫,孙致远,门业堃,任志刚,黄佳,及若林.基于COMSOL电-热-流场分布仿真的高压电缆终端缺陷分析[J].电测与仪表,2025,62(9):100-106.
GuoWei,SunZhiyuan,MenYekun,Ren Zhigang,HuangJia,JiRuolin.Defect analysis of high voltage cable terminal based on COMSOL electric-thermal-flow field distribution simulation[J].Electrical Measurement & Instrumentation,2025,62(9):100-106.
基于COMSOL电-热-流场分布仿真的高压电缆终端缺陷分析
Defect analysis of high voltage cable terminal based on COMSOL electric-thermal-flow field distribution simulation
DOI:10.19753/j.issn1001-1390.2025.09.011
中文关键词:  高压电缆  终端缺陷  电-热场分布  局部进水  漏油
英文关键词:high voltage cable, terminal defects, electric-thermal field distribution, local water inflow, oil leakage
基金项目:北京市电力公司科技项目(SGBJKC022273165
                 
作者中文名作者英文名单位
郭卫GuoWei国网北京市电力公司电力科学研究院
孙致远SunZhiyuan国网北京市电力公司电力科学研究院
门业堃MenYekun国网北京市电力公司电力科学研究院
任志刚Ren Zhigang国网北京市电力公司电力科学研究院
黄佳HuangJia国网北京市电力公司丰台供电公司
及若林JiRuolin国网北京市电力公司丰台供电公司
摘要点击次数: 71
中文摘要:
      针对现有单一物理场模型和两两耦合模型对电力电缆终端缺陷判断准确性不高,提出了一种高压电缆终端电磁场、热场和流体场的耦合模型。对220 kV高压电缆终端缺陷的电-热场特性进行分析。通过使用多物理场仿真软件工具COMSOL对高压电缆终端缺陷(局部进水、漏油)的电-热场特性进行分析。结果表明,电缆终端的局部进水缺陷将导致终端局部发热和不同程度的电场畸变。电缆终端漏油缺陷表面无明显温升,漏油形成的空腔处电场畸变明显,严重时会导致绝缘击穿。在实际应用中,模型结果与实际值误差约在1%之内。该研究为高压电力电缆终端内部缺陷的提前诊断提供了理论支持。
英文摘要:
      A coupling model of electromagnetic field, thermal field and fluid field of high-voltage cable terminal is proposed in view of the low accuracy of existing single physical field model and couple coupling model in judging the defects of power cable terminal. The electric thermal field characteristics of 220 kV high-voltage cable terminal defects are analyzed. By using the multi-physical field simulation software tool COMSOL, the electrical thermal field characteristics of high-voltage cable terminal defects (local water ingress and oil leakage) are analyzed. The results show that the local water ingress defect of the cable terminal will lead to local heating of the terminal and varying degrees of electric field distortion. There is no obvious temperature rise on the surface of the cable terminal oil leakage defect, and the electric field distortion in the cavity formed by oil leakage is obvious, which will lead to insulation breakdown in serious cases. In practical application, the error between the model result and the actual value is about 1%. This study provides theoretical support for the early diagnosis of internal defects in high-voltage power cable terminals.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 社长及主编
    • 期刊荣誉
  • 编委会
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司