• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
谭文锴,唐欣,杨豪杰,柴金超.基于TMR阵列的非接触式电流测量装置及方法[J].电测与仪表,2025,62(2):165-172.
TAN Wenkai,TANG Xin,YANG Haojie,CHAI Jinchao.Non-contact current measuring device and method based on TMR array[J].Electrical Measurement & Instrumentation,2025,62(2):165-172.
基于TMR阵列的非接触式电流测量装置及方法
Non-contact current measuring device and method based on TMR array
DOI:10.19753/j.issn1001-1390.2025.02.020
中文关键词:  隧道磁电阻  传感器阵列  非接触测量  电流测量  误差消除
英文关键词:tunnel magnetoresistance, sensor array, non-contact measurement, current measurement, error elimination
基金项目:国家自然科学基金资助项目(51977013)
           
作者中文名作者英文名单位
谭文锴TAN Wenkai长沙理工大学 电气与信息工程学院
唐欣TANG Xin长沙理工大学 电气与信息工程学院
杨豪杰YANG Haojie长沙理工大学 电气与信息工程学院
柴金超CHAI Jinchao长沙理工大学 电气与信息工程学院
摘要点击次数: 527
中文摘要:
      提出一种由隧穿磁阻(tunneling magnetoresistance,TMR)传感器阵列组成的无需磁芯结构、非接触式的电流检测传感系统。为墙体内暗敷导线的电流测量提供了一个解决方案,适用于漏电流检测与故障定位。分析了通电导线产生磁场的特征,研究了通电导线与传感阵列不同相对位置时的数学模型,提出不同工况下同轴传感器间距的取值方法。同时还分析了无软磁屏蔽装置的信号干扰主要来源以及信号误差的主要原因,提出了信号检测的数学模型,针对不同类型的误差,提出了误差校正方法。最后,对不同工况展开实验,结果证明研制的非接触式电流检测装置具有较好的精确度和线性度,验证了电流测量装置的实用性和测量方法的可行性。
英文摘要:
      A non-contact current sensing system composed of tunneling magnetoresistance (TMR) sensor array without magnetic core structure is proposed. It provides a solution for the current measurement of concealed wires in the wall, which is suitable for leakage current detection and fault location. The characteristics of the magnetic field generated by the electrified wire are analyzed, the mathematical model of the electrified wire and the sensor array at different relative positions is studied, and the value method of the coaxial sensor spacing under different working conditions is proposed. At the same time, the main sources of signal interference and the main causes of signal error of the non-soft magnetic shielding device are analyzed, and the mathematical model of signal detection is proposed, and the error correction methods are proposed for different types of errors. Finally, experiments are carried out under different working conditions, and the results show that the developed non-contact current detection device has good accuracy and linearity, which verifies the practicability of the current measuring device and the feasibility of the measurement method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司