葛志杰,吴天博,韩雪峰,刘磊,张维宁,王健.基于裂相横差保护和边缘计算的干式电抗器在线监测系统[J].电测与仪表,2025,62(10):39-46.
GE Zhijie,WU Tianbo,HANXuefeng,LIU Lei,ZHANG Weining,WANG Jian.Online monitoring system of dry-type reactor based on split-phase transverse differential protection and edge computing[J].Electrical Measurement & Instrumentation,2025,62(10):39-46.
基于裂相横差保护和边缘计算的干式电抗器在线监测系统
Online monitoring system of dry-type reactor based on split-phase transverse differential protection and edge computing
DOI:10.19753/j.issn1001-1390.2025.10.005
中文关键词:  干式电抗器  故障  在线监测系统  裂相横差保护
英文关键词:dry-type reactor, fault, online monitoring system, split-phase transverse differential protection
基金项目:国网新疆电力有限公司科技项目(5230DK22011T)
                 
作者中文名作者英文名单位
葛志杰GE Zhijie国网新疆电力有限公司电力科学研究院
吴天博WU Tianbo国网新疆电力有限公司电力科学研究院
韩雪峰HANXuefeng国网新疆电力有限公司电力科学研究院
刘磊LIU Lei国网新疆电力有限公司电力科学研究院
张维宁ZHANG Weining国网新疆电力有限公司电力科学研究院
王健WANG Jian新疆信息产业有限责任公司
摘要点击次数: 28
中文摘要:
      电力系统中干式空心电抗器通常工作于高压环境,其自身的短路和断路故障是目前干式电抗器主要的故障因素。针对干式电抗器故障检测灵敏度低、测量滞后、容易误判等问题,文中提出了基于裂相横差保护的干式电抗器边缘在线监测系统。文章论述了基于干式空心电抗器星臂电流裂相横差保护的边缘监测系统结构,设计了该边缘监测系统所需的取能、电流采集和数据分析处理等软硬件系统,通过短路和断路实验验证了所述方法和系统在干式空心电抗器短路和断路故障监测中的有效性。
英文摘要:
      In power system, dry-type air-core reactor usually works in high-voltage environment and its own short-circuit and open-circuit faults are the main fault factors of dry-type reactor at present. In order to solve the problems of low detection sensitivity, measurement delay and easy misjudgment of dry-type reactor fault, an online monitoring system for dry-type reactor edge based on split-phase transverse differential protection is proposed in this paper. This paper discusses the structure of the edge monitoring system based on the star-arm currents split-phase transverse differential protection of the dry-type air-core reactor, it designs the software and hardware systems required by the edge monitoring system, such as energy acquisition, current acquisition and data analysis and processing modules. The effectiveness of the proposed method and system in the short-circuit and open -circuit fault monitoring of dry-type air-core reactor is verified through experiments.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 社长及主编
    • 期刊荣誉
  • 编委会
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司