荆志朋,柴林杰,胡诗尧.基于改进LSTM-VAE的配电网异常负荷检测方法研究[J].电测与仪表,2024,61(9):71-76.
JING Zhipeng,CHAI linjie,HU Shiyao.Research on abnormal load detection method for distribution network based on improved LSTM-VAE[J].Electrical Measurement & Instrumentation,2024,61(9):71-76.
基于改进LSTM-VAE的配电网异常负荷检测方法研究
Research on abnormal load detection method for distribution network based on improved LSTM-VAE
DOI:10.19753/j.issn1001-1390.2024.09.009
中文关键词:  配电网  负荷数据  异常检测  长短期记忆网络  变分自编码器
英文关键词:distribution network, load data, abnormal detection, long short-term memory, variational auto-encoder
基金项目:国家电网公司科技项目(5204JY20000B)
        
作者中文名作者英文名单位
荆志朋JING Zhipeng国网河北省电力有限公司经济技术研究院
柴林杰CHAI linjie国网河北省电力有限公司经济技术研究院
胡诗尧HU Shiyao国网河北省电力有限公司经济技术研究院
摘要点击次数: 480
中文摘要:
      针对目前配电网负荷数据异常检测方法准确率低的问题,提出将改进的长短期记忆网络和变分自编码器相结合用的配电网负荷异常检测方法。通过残差结构对长短期记忆网络进行优化,提高特征学习能力,并将优化后的长短期记忆网络替换变分自编码器的BP神经网络层(编码和解码),可以更好地获得负荷数据的时间相关性。通过与常规检测方法的试验对比,验证了所提检测方法的优越性。结果表明,相比于常规负荷数据异常检测方法,所提方法具有更好的检测准确率,异常检测准确率为97.30%,比未引入残差结构提高了1.70%,比LSTM模型提高了7.00%,比PSO-PFCM模型提高了4.80%。可为配电网自动化的发展提供一定的参考。
英文摘要:
      The accuracy of anomaly detection in current distribution network load data anomaly detection is low, a load anomaly detection method for distribution network is proposed, which combines the improved long short-term memory network with variational auto-encoder. Long short-term memory network is optimized through residual structure to improve feature learning ability, and the optimized long short-term memory network replaces the BP neural network layer (encoding and decoding) of the variational auto-encoder, which can better obtain the time correlation of load data. By comparing with conventional testing methods, the superiority of the proposed detection method has been verified. The results indicate that, compared to conventional load data anomaly detection methods, the proposed method has better detection accuracy, the accuracy rate of anomaly detection reaches 97.30%, compared to not introducing residual structure, it has increased by 1.70%, improved by 7.00% compared to the LSTM model,improved by 4.80% compared to the PSO-PFCM model, which can provide a certain reference for the development of distribution network automation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司