蒋群,徐永进,李先志,廖绍成,谢烽.基于AMI 数据及电能表计量点误差远程诊断的低压失准模型求解方法[J].电测与仪表,2026,63(3):193-200.
Jiang Qun,Xu Yongjin,Li Xianzhi,Liao Shaocheng,Xie Feng.Solution of low-voltage loss model based on AMI data and remote error detection for smart electricity meter measurement[J].Electrical Measurement & Instrumentation,2026,63(3):193-200.
基于AMI 数据及电能表计量点误差远程诊断的低压失准模型求解方法
Solution of low-voltage loss model based on AMI data and remote error detection for smart electricity meter measurement
DOI:10.19753/j.issn1001-1390.2026.03.020
中文关键词:  AMI  智能电能表  误差检测  低压线损模型
英文关键词:AMI, smart electricity meter, error detection, low-voltage line loss model
基金项目:国网浙江省电力有限公司科技项目(5211YF200053)
              
作者中文名作者英文名单位
蒋群Jiang Qun国网浙江省电力有限公司
徐永进Xu Yongjin国网浙江省电力有限公司
李先志Li Xianzhi北京志翔科技股份有限公司
廖绍成Liao Shaocheng国网浙江省电力有限公司
谢烽Xie Feng国网浙江省电力有限公司
摘要点击次数: 411
中文摘要:
      针对低压电网的失准模型,提出了一种基于AMI(advanced metering infrastructure)数据和电能表计量点误差的求解方法。该方法通过分析低压电网线损模型的能量守恒方程组,基于线阻系数的物理含义,将受限岭回归方法引入线损模型,在理论上证明了低压失准模型求解等价于有约束条件的最优化问题。为验证所提出方法的有效性,在实验室仿真数据和现场真实数据上进行了盲测,结果表明该方法在小超差计量点的检测上具有较高的命中率和检出率,显示出良好的工程实用性和经济价值。
英文摘要:
      In response to the inaccuracy model of low-voltage power grid, a solution method based on AMI(advanced metering infrastructure) data and metering point errors of electricity meters is proposed. This method analyzes the energy conservation equation set of the low-voltage power grid line loss model, introduces the constrained ridge regression method into the line loss model based on the physical meaning of the line resistance coefficient, and theoretically proves that the solution of the low-voltage inaccuracy model is equivalent to an optimization problem with constrained conditions. To validate the effectiveness of the proposed method, blind tests are conducted on both laboratory simulation data and real-world data, and the results indicate that the method has a high hit rate and detection rate for small out-of-tolerance metering points, demonstrating good engineering practicality and economic value.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 社长及主编
    • 期刊荣誉
  • 编委会
    • 主任委员
    • 编委名单
    • 青年编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司