王思韡,刘型志,宣姝,毛茜,要文波.基于线损等效的视在功率和功率因数计算方法研究[J].电测与仪表,2024,61(9):65-70.
WANG SIWEI,LIU XINGZHI,XUAN SHU,MAO QIAN,YAO WENBO.Research on apparent power and power factor calculation methods based on line loss equivalence[J].Electrical Measurement & Instrumentation,2024,61(9):65-70.
基于线损等效的视在功率和功率因数计算方法研究
Research on apparent power and power factor calculation methods based on line loss equivalence
DOI:10.19753/j.issn1001-1390.2024.09.008
中文关键词:  非正弦不平衡系统  功率因数  视在功率  功率损耗等效  智能电能表
英文关键词:non-sinusoidal unbalanced systems, power factor, apparent power, power loss equivalence, smart electricity meter
基金项目:国网重庆市电力公司科技项目资助(2022渝电科技18#)
              
作者中文名作者英文名单位
王思韡WANG SIWEI国网重庆市电力公司营销服务中心
刘型志LIU XINGZHI国网重庆市电力公司营销服务中心
宣姝XUAN SHU国网重庆市电力公司营销服务中心
毛茜MAO QIAN国网重庆市电力公司营销服务中心
要文波YAO WENBO国网重庆市电力公司营销服务中心
摘要点击次数: 452
中文摘要:
      分析了三相严重不平衡条件下现有功率因数的计算结果,指出了现有计算方法在反映实际线路利用率情况存在的不足。基于线路功率损耗等效原理,提出了一种能够准确反映实际线路利用率的功率因数和视在功率计算新方法。给出了现有智能电能表实现等效功率因数和视在功率计算的升级方案,同时以高准确度智能电能表作为测试平台,与现有功率因数进行三相非正弦不平衡试验条件下的对比测试。数据分析表明,与现有功率因数和视在功率相比,所提出的功率因数和视在功率新方法能够如实反映实际线路利用率情况,能够为功率因数的改善提供合理依据。
英文摘要:
      This paper analyzes the calculation results of the existing power factor under the condition of three-phase severe unbalance, and points out the shortcomings of the existing calculation methods in reflecting the actual line utilization. Based on the principle of line power loss equivalence, a new power factor and apparent power calculation method that can accurately reflect the actual line utilization rate is proposed. The upgrade scheme of the existing smart electricity meter to realize the effective power factor and apparent power measurement is given, and the high-accuracy smart electricity meter is used as the test platform to carry out the comparative test with the existing power factor under the condition of three-phase non-sinusoidal unbalance test. The data analysis shows that, compared with the existing power factor and apparent power, the proposed power factor and apparent power can faithfully reflect the actual line utilization rate, which can provide a reasonable basis for the improvement of power factor.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司