容春艳,程蓉,胡诗尧,苏钟焕,王贵娟.分裂绕组高阻抗电力变压器短路特性研究[J].电测与仪表,2024,61(12):104-113.
RONG Chunyan,CHENG Rong,HU Shiyao,SU Zhonghuan,WANG Guijuan.Research on short-circuit characteristics of split-winding high impedance power transformer[J].Electrical Measurement & Instrumentation,2024,61(12):104-113.
分裂绕组高阻抗电力变压器短路特性研究
Research on short-circuit characteristics of split-winding high impedance power transformer
DOI:10.19753/j.issn1001-1390.2024.12.014
中文关键词:  电力变压器  高阻抗  短路试验  有限元法
英文关键词:power transformer,high impedance,short-circuit test,finite element method
基金项目:国网河北省电力有限公司科技项目(5204JY210005)
              
作者中文名作者英文名单位
容春艳RONG Chunyan国网河北省电力有限公司经济技术研究院,石家庄 050000
程蓉CHENG Rong国网河北省电力有限公司经济技术研究院,石家庄 050000
胡诗尧HU Shiyao国网河北省电力有限公司经济技术研究院,石家庄 050000
苏钟焕SU Zhonghuan特变电工衡阳变压器有限公司,湖南 衡阳 421007
王贵娟WANG Guijuan特变电工衡阳变压器有限公司,湖南 衡阳 421007
摘要点击次数: 380
中文摘要:
      文中对比了分裂绕组、高压内置以及串抗结构三种高阻抗电力变压器的优缺点,通过有限元分析得到了分裂绕组高阻抗电力变压器高中短路和中低短路的漏磁分布,对变压器进行了承受短路能力判断,并通过短路试验论证了研究结果的正确性。仿真与试验数据表明,分裂绕组高阻抗变压器虽然存在结构尺寸偏大,极限分接阻抗变化大等不利因素,但此结构相较传统变压器具有更强的承受短路能力。同时,试验后中低阻抗变化率0.49%大于高中工况0.15%,说明即使采用了高阻抗结构,低压绕组承受短路能力依然弱于高、中绕组,在实际应用中应重点关注。
英文摘要:
      This paper firstly compares the advantages and disadvantages of three kinds of high impedance power transformers, namely split winding, high voltage built-in and series resistance structure. The magnetic leakage distribution of high and low short-circuit and medium short-circuit in high impedance power transformer with split winding is obtained by finite element analysis. The short-circuit ability of the transformer is judged, and the correctness of the research results is proved by short-circuit test. The simulation and test data show that the high-impedance transformer with split winding has a stronger short-circuit resistance than the traditional transformer, although it has some disadvantages such as larger structure size and larger limit tapping impedance change. At the same time, after the test, the change rate of low and medium impedance 0.49% is greater than that of high and medium conditions 0.15%, indicating that even if the high-impedance structure is adopted, the short-circuit resistance of the low-voltage winding is still weaker than that of the high and medium winding, which should be paid attention to in practical applications.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司