• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于FAHP的10kV长线路节能降损能效评价研究
A Method to Evaluate Effectiveness of the 10kV long line Energy Loss Reduction Based on FAHP
Received:August 28, 2013  Revised:August 28, 2013
DOI:
中文关键词: 降损节能  模糊层次分析法  评价
英文关键词: Energy Conservation  Fuzzy Analytic Hierarchy Process(FAHP)  evaluation
基金项目:本文工作受到甘肃省电力公司科技项目“10kV长线路系统通用降损方法与节能技术研究”(GS1303-KJ-033)资助
Author NameAffiliationE-mail
Wu Wei-li* Dept of Electronics and Information Engineering,Yili Normal University,Yining wwllxm@163.com 
Zhang HongJun Gansu Provincial Power Company,Lanzhou,Gansu  
Liu Kefa Gansu Provincial Power Company,Lanzhou,Gansu  
Zhao Jun Gansu Provincial Power Company,Lanzhou,Gansu  
Liu Lian-guang Deptof Electronic and Electrical Engineering,North China Electric Power University,Beijing, China  
Han long yan Dept.of Electronic and Electrical Engineering, North China Electric Power University,Beijing,102206 China  
Hits: 1807
Download times: 628
中文摘要:
      在综合研究我国农网降损节能设计与改造的基础上,构建了10kV长线路降损节能方案的评价指标体系, 采用模糊层次分析法进行节能评价,并以实例验证了评价模型的可行性,以期能为农网10kV长线路提供行之有效的综合降损措施。
英文摘要:
      In the comprehensive study of rural power loss reduction and energy-saving design, the method of 10kV long lines energy loss reduction evaluation is constructed by using fuzzy analytic hierarchy process. The calculation result of the actual project demonstrate the feasibility evaluation model, which can provide the reference for the 10kV rural long lines comprehensive loss reduction measures.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd