基于改进同步时间法梯级水电站群间协调控制策略的研究
Study on the Coordinate Control Scheme Based on Improved Synchronous Time Method for Cascade Hydropower Plants
Received:September 09, 2013  Revised:September 09, 2013
DOI:
中文关键词: 梯级水电站  AGC控制  节能调度  改进同步时间法  协调控制策略
英文关键词: Cascade  Hydropower plants  AGC  Energy saving dispatch  Improved synchronous time method  Coordinated control strategy
基金项目:国家自然科学基金项目(510670001);贵州省科技厅基金项目(黔科合J字[2008]2212号);贵州大学博士基金项目(贵大人基合字2007-019号)
Author NameAffiliationE-mail
YUAN Xu-Feng* College of Electrical Engineering,Guizhou University,Guiyang,550025 17015676@qq.com 
LONG Yan College of Electrical Engineering,Guizhou University,Guiyang,550025  
XU Wei-Jie College of Electrical Engineering,Guizhou University,Guiyang,550025  
XIONG Wei College of Electrical Engineering,Guizhou University,Guiyang,550025  
ZOU Xiao-Song College of Electrical Engineering,Guizhou University,Guiyang,550025  
Hits: 1643
Download times: 634
中文摘要:
      利用GPS对时功能,提出了一种改进同步时间法来保证各个调频电厂的时间同步,避免频差积分差异,为调频机组分散协调控制奠定了基础;以省级电网中的梯级水电站群为研究对象,提出了一种基于改进同步时间法的梯级水电站群AGC协调控制策略,实现了各梯级水电站所接入的地区电网间联络线负荷功率频率偏差ACE的控制,保证了区域电网频率恒定。以3机9节点系统为例,利用PSCAD/EMTDC软件构建了三区域等值模型及梯级水电站协调控制策略,验证了所提算法的可行性及有效性。
英文摘要:
      Using the function of GPS time transfer, an improved synchronization time method has been put forward to ensure clocks of each power plant participating in frequency regulation synchronized, and to avoid the integral difference of frequency offset, so a coordinated control can be realized for decentralized frequency regulation. Taking Cascade hydropower plants in a provincial power grid as the study case, this paper has put forward a coordinated control scheme based on improved synchronization time for cascade hydropower plant group of AGC, to realize ACE control of load power frequency deviation on tie-lines of each power plant connected to the grid, and to keep the regional power grid frequency constant. Finally, by building a three regional equivalent model and a control scheme of cascade hydropower plants in PSCAD/EMTDC, the proposed method is tested on 3-geneator 9-bus system to verify its feasibility and efficiency.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd