• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
双反激型光伏并网微逆变器的建模及控制
Modeling and Control of PV Grid-connected Micro InverterBased on Interleaved Parallel Flyback Converter
Received:September 13, 2013  Revised:September 13, 2013
DOI:
中文关键词: 交错并联反激  控制策略  直接电流源型  小信号控制模型  光伏并网发电
英文关键词: interleaved  parallel flyback, control  strategy, direct  current source, small-signal  control model,PV  grid-connected  power generation
基金项目:中国博士后基金资助项目(20110491331);江苏省产学研前瞻性项目资助(BY2013063-01)
Author NameAffiliationE-mail
ZHAO Qi-qi* Institute of Information Engineering,Yangzhou University zhao_qiqi@126.com 
FANG Yu Institute of Information Engineering,Yangzhou University  
ZHANG Jin-yin Institute of Information Engineering,Yangzhou University  
LI Wen Institute of Information Engineering,Yangzhou University  
WANG Qi Institute of Information Engineering,Yangzhou University  
Hits: 2154
Download times: 708
中文摘要:
      对交错并联双反激微型并网逆变器进行研究,阐述了单相并网微型逆变器的工作原理,并对其控制策略、关键性技术给予了详细的分析。在交错并联双反激光伏并网发电微型逆变器系统中,对电网的跟踪控制直接影响到输出电能的质量和系统的运行效率,是并网系统的核心和关键。选择直接电流源型并网控制方式,通过对并网电流的直接控制,使并网电流与电网电压保持同频率、同相位,从而实现并网。给出了主功率电路的等效数学模型,并推导出了其对应的小信号模型,继而给出了电流环路的方案设计,并通过仿真和实验来验证控制方案的可行性。
英文摘要:
      An interleaved parallel flyback grid-connected micro inverter was focused on, and its grid-connected operation principle and control strategy were presented; what is more, the key techniques were also discussed in the paper. In photovoltaic (PV)grid-connected micro-inverter system, the tracking control is the core and key technology of the system, and directly affects the output power quality and system efficiency. The direct current control has been chosen to synchronize the current frequency and phase with the grid. The Mathematical model of main power circuit is made and the small-signal control model is deduced. Then, current loop control parameters are designed and presented, and finally the simulation and experimental results verify the feasibility of the control strategy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd