• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
LCL滤波单相并网逆变器电流加权控制研究
LCL filterSweighted currentScontrol base on single-phase grid-connected inverter
Received:September 28, 2013  Revised:September 28, 2013
DOI:
中文关键词: 单相并网逆变器  LCL滤波  电流加权控制  稳定性
英文关键词: single-phase grid-conneted inverter ,LCL filter, current weight control, stability
基金项目:
Author NameAffiliationE-mail
YANG Feng* Guangxi Power Grid Corp of Yulin Power Supply Bureau paopaoma@foxmail.com 
CAI Zhen-yu Yuchai Marine Power Co., Ltd  
Hits: 1885
Download times: 1156
中文摘要:
      针对并网逆变器LCL滤波器直接电流控制出现的稳定性和控制精度等问题,提出了一种电流加权控制的策略。控制方案采用逆变器侧和电网侧电流加权反馈方式,调节电流反馈系数可以改善系统性能,还分析了电网电感对控制策略的影响。为了验证理论的正确性和控制策略的有效性,在Matlab/Simulink中搭建额定功率5kW的LCL加权电流控制仿真系统。仿真结果表明,电流加权控制稳定裕度大稳态精度高,馈入电网电流总体谐波畸变率小,功率因数高;另外,电网阻抗增大时不影响系统的稳定性,入网电流谐波却进一步下降,功率因数也略有下降。
英文摘要:
      A weight current control strategy was presented to solve stability and control accuracy of grid-connected inverter with LCL filter by direct current control. The control scheme used inverter side current and grid side current as feedback signal. Current feedback factor could change system performance.It also analyzed the influence on control strategy by grid inductance. A 5kW LCL weighted current control simulation system was built in Matlab/Simulink to verify the correctness of the theory and the control strategy. The simulation results show that, the current weighted control had high stability margin and steady state accuracy, grid current total harmonic distortion rate was very low, the power factor was very high; in addition, increasing grid impedance did not affect the stability of the system,but current harmonic was further reduced, and the power factor was lower .
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd