• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
大功率H桥逆变器损耗的精确计算方法及其应用
Precise Calculation Method Of High Power H-bridge Inverter And Its Applications
Received:November 28, 2013  Revised:November 28, 2013
DOI:
中文关键词: H桥逆变器  开关损耗  开关能量曲线  双脉冲测试
英文关键词: H-bridge Inverter  Switching loss  Switching energy curve  Double pulse test
基金项目:
Author NameAffiliationE-mail
Ren Qi-mei* Henan University of Urban Construction rqm_2013@163.com 
Jiang Jian Henan University of Urban Construction  
Hits: 2467
Download times: 1631
中文摘要:
      大功率H桥逆变器中广泛采用IGBT作为开关器件,传统的IGBT开关损耗计算是基于供应商提供的开关能量曲线,而该曲线上所提供的开关能量与逆变器实际运行时的数据有较大出入。为此,提出了一套完整的大功率H桥逆变器的损耗分析与精确计算方法。逆变器损耗主要包括IGBT损耗和电解电容损耗,而IGBT损耗又包括导通损耗、开通损耗、关断损耗和反向恢复损耗。给出了各类损耗的定量计算方法,并且采用了双脉冲测试方法获得实际开关能量曲线,因此计算结果更加精确。搭建了一台3.45kVA的实验样机,1kHz开关频率下满载运行时,计算损耗为218W,实测损耗为210W。实验结果验证了所提出的分析与计算方法的准确性。
英文摘要:
      IGBT is widely used in high power H-bridge inverter. Traditional IGBT switching loss calculation method is based on the switching energy curve provided by supplier, which is quite different from real switching energy. Therefore, a precise calculation method of high power H-bridge inverter was proposed. The power loss of inverter was composed of IGBT power loss and capacitor power loss, and the IGBT power loss was composed of conduction power loss, turn-on power loss, turn-off power loss and reverse recovery power loss. Calcution method of different power loss was presented and real switching energy curve was obtained using double pulse test resulting of more precise calculation. Finally, a 3.45kVA prototype was build, and the calculated power loss is 210W while the measured power loss was 210W under 1kHz switching frequency at full load. The experimental result verifies the accuracy of the proposed method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd