• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
用于微网逆变器并联的控制策略
A Control Strategy for Parallel Operation of Multi-inverters in Microgrid
Received:November 28, 2013  Revised:November 28, 2013
DOI:
中文关键词: 下垂控制  逆变器并联  功率精分  阻性虚拟阻抗  电压反馈
英文关键词: droop  control, inverter  parallel, proportional  load sharing, resistive  virtual impedance, voltage  fed
基金项目:广东省引进创新科研团队计划资助(项目编号:2011N015 );国家863高技术基金项目(2011AA05A107)。
Author NameAffiliationE-mail
ZHANG Guo-rong Research Center for Photovoltaic System Engineering Hefei University of Technology,Ministry of Education zhanggrcao@163.com 
XIE Jie* Research Center for Photovoltaic System Engineering Hefei University of Technology,Ministry of Education 935380605@qq.com 
Hits: 1892
Download times: 1126
中文摘要:
      对于包含多个逆变器的微电网系统,使用传统下垂控制法会造成逆变器间环流及功率分配不均,这是由于逆变器的输出阻抗及线路阻抗各有差别。本文首先介绍了传统下垂控制方法,并基于此,分析逆变器输出阻抗为阻性时的功率分配情况,指出传统下垂控制的缺陷。随后,为了达到功率精确分配及等效输出阻抗为阻性的要求,即满足能够正确使用传统下垂控制法的前提条件,引入满足条件的阻性虚拟阻抗,并给出该虚拟阻抗的具体添加位置。针对输出电压偏差,通过在传统下垂控制法中添加电压反馈环节来解决。最后,仿真结果表明了该改进下垂控制策略的正确性和有效性。
英文摘要:
      Since the output impedance of the inverters and common connection point areSdifferent, for multi-inverter parallel micro-grid system, the application of traditional droop control method will lead to increased circulation andSuneven distribution among paralleled power inverters. In this paper, firstly, traditional droop control method and the impact of output impedance are analyzed. Then it finds out the inherent limitations of the conventional droop control scheme. So to overcome the shortcomings of traditional droop control method, it introduced resistive virtual impedance , both changes the properties of equivalent output impedance and brings précised power sharing of the parallel-operated inverter in Microgrid. Additional of voltage fed back in traditional droop control can solve voltage deviation. Simulation results demonstrate that the control strategy is correct and effective.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd