文章摘要
河西走廊高土壤电阻率地区地网接地接电阻测量与分析
The power frequency grounding resistance measurement and analysis of grounding-net in high resistively soil area of Hexi corridor regions
Received:December 02, 2013  Revised:December 02, 2013
DOI:
中文关键词: 河西走廊  接地系统 接地电阻  变电站
英文关键词: Hexi  Corridor region,grounding-net,grounding  resistance measurement, transformer  substation
基金项目:
Author NameAffiliationE-mail
Chunjiang-HU* GSEPRI sthcj@126.com 
Yushuo-wu The power frequency grounding resistance measurement and analysis of grounding-net in high resistively soil area of Hexi corridor regions  
Zhihua-YANG GSEPRI  
Dingjun-WEN Gansu Electric Power Research Institute  
Kai-Zhang Gansu Electric Power Research Institute  
Hits: 2036
Download times: 930
中文摘要:
      河西走廊地区以地表多岩石戈壁地貌为主要特征,土壤电阻率高,此类地区变电站接地系统的处理及测量存在许多技术困难。在该地区测量地网接地电阻时会遇到注入测量电流困难、测试设备试验容量难以满足测量需求、各种干扰因素复杂难以测得可信结果等问题。本文以河区走廊地区某变电站接地网测试为例,选择合理的理论测量模型并对测量模型及结果进行了分析,为设备的安全运行提供基础数据,也为今后该类地区地网测试提供了参考。
英文摘要:
      Hexi Corridor region is characterized by the Gobi desert with high resistively soil.It imposes many difficulties on grounding-net processing and measurement in substations of the area. It brings many difficulties such as obtaining enough measuring electric current injection, and capacity shortage of the equipment. Due to the various disturbances, it’s frequently difficult to measure the reliable results. This paper discussed the grounding resistance measurement for a transformer substation as example in Hexi Corridor region. By selection and analysis of appropriate measurement model, It provides a fundamental data for safety operation of the equipment so as to provide a reference for similar grounding resistance measurement.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd