• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种三相不平衡度相量快速算法
A Fast Three-Phase Unbalance Vector Calculation Method
Received:December 04, 2013  Revised:December 04, 2013
DOI:
中文关键词: 三相不平衡  相量  代数计算  电能质量
英文关键词: three-phase unbalance  vector  algebra operations  power quality
基金项目:国家自然科学(61370014、51377049)
Author NameAffiliationE-mail
Cheng Da College of Electrical and Information Engineering,HuNan University,Changsha,410082 ambition8@126.com 
Wen He College of Electrical and Information Engineering,HuNan University,Changsha,410082  
Teng Zhao-sheng* College of Electrical and Information Engineering,HuNan University,Changsha,410082 tengzs@126.com 
Tan Xia College of Electrical and Information Engineering,HuNan University,Changsha,410082  
Hits: 1278
Download times: 880
中文摘要:
      三相不平衡度是衡量电能质量的重要指标之一。电量的不平衡状态严重危及电器的使用安全,甚至导致用电设备损坏,因此对三相不平衡度的监测非常重要。国标GB/T 15543-2009与国际标准IEC-6100-4-27给出的算法中,要测出三相不平衡度需要进行复杂的相量运算。在微处理器中,若按照标准所给的算法进行计算难以同时保证运算的效率与精度要求。本文基于几何原理将复杂的相量运算转化为简单的代数运算,提出了三相不平衡度相量快速算法。仿真与实验证明本算法能达到标准规定的精度且高效,适合具有浮点运算单元的微处理器中使用。
英文摘要:
      According to the real situation of lack of monitoring device for stand-alone PV power plant in rural areas of china, this paper introduce a data monitoring system which based on embedded platform. This system adopts modularization design which includes signal collecting, DSP signal processing and ARM processing platform. The accuracy of data counting is apparently improved because the data collecting unit adopts 16 channels synchronous sampling; system can collects, counts, displays and stores plant operation data for system analysis effectively, since combination of DSP and ARM. This solution is useful to design monitoring system which will be more portable, lower cost and energy consumption.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd