不对称故障下双馈感应发电机转子电压分析
Low-voltage ride-through area analysis of doubly fed induction generator duringasymmetric faults
Received:December 16, 2013  Revised:December 16, 2013
DOI:
中文关键词: 双馈感应发电机  低电压穿越  撬棒保护  不对称故障
英文关键词: doubly fed induction  low voltage ride through  crowbar protection  asymmetric fault
基金项目:国家自然科学(51207018);吉林省科技发展计划项目(20130522174JH)
Author NameAffiliationE-mail
WANG Su* School of Electrical Engineering,Northeast Dianli University dianzi072wangsu@163.com 
CUI Yang School of Electrical Engineering,Northeast Dianli University  
fengdongdong DONGFANG TURBINE Dongfang Electric(tongliao) Wind Power Technology co.,Ltd.  
Hits: 1744
Download times: 755
中文摘要:
      针对不对称故障引起的电压跌落,求解得出三种不对称故障期间转子感应电动势峰值,结合对转子侧变流器控制能力的分析揭示了转子侧过流的根本原因。以转子侧变流器的最大控制电压为准则,推导出三种不对称故障的低电压穿越域。采用PSCAD搭建带有撬棒保护Crowbar的双馈风电机组暂态模型,仿真结果验证了本文所提出的低电压穿越域的正确性。
英文摘要:
      According to the voltage dip caused by asymmetric fault, the peak of rotor voltage during the three asymmetric faults is calculated. The root cause of the rotor over current has been revealed combined with the analysis of the control ability of the rotor side converter. On the basis of the maximum control voltage of the rotor side converter, the low voltage ride through area of different asymmetric fault is deduced. The transient model of doubly fed induction generator with crowbar circuit has been built by PSCAD. The low voltage ride through area has been proved to be correct by the simulation results.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd