CDSC在单相电网同步锁相技术中的应用
Single Phase Grid Synchronization Technology Based on Cascade Signal Delay Cancellation
Received:December 27, 2013  Revised:December 27, 2013
DOI:
中文关键词: 单相锁相环  级联信号延时消除  同步参考坐标变换  频率反馈环  电网同步
英文关键词: Single  phase PLL, Cascade  Signal Delay  Cancellation, Synchronous  reference frame  transformation, frequency-feedback  loop, Grid  Synchronization
基金项目:
Author NameAffiliationE-mail
SUN Li* Southwest Jiaotong University sunlee1216@163.com 
YANG Gui-ying School of Electrical Engineering,Southwest Jiaotong University  
ZHUANG Shen-Xian School of Electrical Engineering,Southwest Jiaotong University  
Hits: 1606
Download times: 942
中文摘要:
      针对非理想电网环境下单相锁相环同步问题,本文提出一种基于级联信号延时消除(CDSC)的单相锁相环,首先对仅有单相输入下的坐标变换结果进行分析,得出各种非理想电网状态下单相信号输入的同步旋转坐标变换的输出特性。结合带有频率反馈环路的级联信号延时消除法能够快速有效的抑制如直流分量、谐波、相位突变等非理想电网环境给同步参考坐标变换输出带来的不良影响,从而达到准确的跟踪单相电网基波电压幅值、相位和频率自适应的目的。该方法无需构造输入电压信号的虚拟正交信号,算法简单且硬件上容易实现。仿真和实验结果验证所提出的锁相环在非理想电网环境下可以快速准确的跟踪输入电网电压信号的相位、频率和幅值,同时满足系统的稳定性。
英文摘要:
      In this paper a kind of single phase lock loop based on cascade signal delay cancellation was proposed to deal with the synchronization of single phase grid under undesirable grid environment. Frist, only one phase signal is considered as input of Park-transformation while the others are kept zero. The features of output are analyzed at the same time. For tracking the amplitude, phase and the frequency adaptation of grid fundamental component fast and accurately. Within the frequency feedback loop the cascade signal delay cancellation method can eliminate adverse effects in output of synchronous reference frame transformation under fault grid condition such as DC component, harmonic, phase jump, etc. This method needn’t construct virtual orthogonal signal. Proposed algorithm is simple and easy implement. The effectiveness of the proposed method is verified by simulation and experiment results.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd